5 OPERATION
5.11.2

Middle wire guide

1.
Apply a small amount of pressure to
the middle wire guide clip and
remove the middle wire guide (A).
2.
Push in the correct type of wire
guide (according to the WEAR
PARTS appendix). The clip
automatically locks the wire guide
when in the correct position.
5.11.3

Outlet wire guide

1.
Remove the lower right feed roller
(see the "Changing feed rollers"
section).
2.
Remove the middle wire guide (see
the "Middle wire guide" section).
3.
Unlock the outlet wire guide quick
lock (A) by folding it out.
4.
Remove the outlet wire guide (B).
5.
Install the correct outlet wire guide
(according to the WEAR PARTS
appendix).
6.
Lock the new outlet wire guide into
place using the wire guide quick
lock (A).
7.
Reattach the second pair of feed
rollers and reapply the roller
pressure (see the "Changing feed
rollers" section).
5.12

Roller pressure

The roller pressure should be adjusted separately on each tensioner unit, depending on the
material and diameter of the wire used.
Start by making sure that the wire moves smoothly through the wire guide. Then set the
pressure of the wire feeder's pressure rollers. It is important that the pressure is not too high.