Advertisement

3 TECHNICAL DATA
Robust Feed PRO, valid from serial no. 904-xxx-xxxx
60% duty cycle
100% duty cycle
Enclosure class
*) Maximum speed is guaranteed across the whole speed range for all wires. For 2.0-mm
solid wires and 2.4-mm cored wires, speed is guaranteed within the speed range of
0.8–8.0 m/min (32–315 in./min). The Robust Feed PRO will be able to achieve higher
feeding speed above 8.0 m/min (315 in./min), but with higher tolerances.
Duty cycle
The duty cycle refers to the time as a percentage of a ten-minute period that you can weld or
cut at a certain load without overloading.
Enclosure class
The IP code indicates the enclosure class, i.e. the degree of protection against penetration
by solid objects or water.
Equipment with the IP44 marking is intended for indoor and outdoor use and can withstand
rain from all directions.
0463 691 001
500 A
400 A
IP44
- 14 -
© ESAB AB 2019