Torch Connection - ESAB MobileFeed 301 AVS Instruction Manual

Hide thumbs Also See for MobileFeed 301 AVS:
Table of Contents

Advertisement

4 INSTALLATION
Brake disc friction should provide enough drag to keep the wire spool from spinning freely
after the wire feed stops.
The brake hub is adjusted when delivered, if adjustment is required, follow the instructions
below. Adjust the brake hub so that wire is slightly slack when wire feed stops.
1.
To increase the braking torque, use an 5/16" (8 mm) allen key and turn the drag
adjusting screw (1) clockwise.
2.
To reduce the braking torque, use an 5/16" (8 mm) allen key and turn the drag
adjusting screw (1) counterclockwise.
4.7

Torch connection

CAUTION!
Make sure the chosen torch has the correct rating for the welding current to be
used, has the correct size and type of liner and has the correct contact tip and
guide tube.
WARNING!
Turn off the power to the welding power source and the wire feeder before
making any connections between the wire feeder and the welding power source.
The torch adaptor on the MobileFeed connects directly to the wire feeder wire drive
assembly, power and shielding gas supply.
1.
Line up the torch connector with the wire feeder adaptor and push on firmly.
2.
Hand tighten the locking collar on the Euro connector.
0558 012 634
- 12 -
© ESAB AB 2016

Advertisement

Table of Contents
loading

Table of Contents