8. Reference
Checkpoints before service request (Continued)
SYMPTOM
•
Keypad is not properly
worked
•
•
Warming drawer is not
worked
•
•
Oven lamp is not
worked
•
Smell or smoke is
•
occurred during the
very first operation.
LED display is a little
•
dim or dark, so it
makes uncomfortable
to see .
There is no buzzer
•
beep sound while
keypad is being
touched .
•
Cooktop flame with LP
is extraordinary short .
•
Cooktop flame with LP
is extraordinary long
(with yellow flame)
•
Convection fan is
•
not rotated .
This document can not be used without Samsung's authorization.
DIAGNOSIS
Make sure that keypad cable on Display
PCB is in normal state .
Make sure connector (CN201) on Display
PCB or PCB pattern .
Check a relay(RY506) and a
terminal(T508) at warming drawer .
Measure whether resistance of warming
drawer heater is in normal extent or not .
Check the oven lamp's relay and
connector (CN501) .
Measure the resistance of both ends of
lamp terminal .
This is in normal state .
LED display is inferior .
Check the state of buzzer on main PCB
and whether PCB pattern has a short
circuit or has been open .
Check the cap of regulator .
Check the injector nozzle .
Check whether Convection fan relay on
main PCB and connector(CN501) is in
normal .
Make sure whether harness between
Connector on main PCB and Connector
(CN501) on main PCB is connected in
normal .
90
REMEDY
•
Replace the keypad in case that it is
loosen or disconnected .
•
Replace or repair the keypad in case
cable is loosen or disconnected .
•
Replace the terminal(T508) or relay
(RY506) .
•
Replace a main PCB .
•
Replace a warming drawer heater .
•
Replace or repair if the harness is loosen
or disconnected .
•
Replace oven relay(RY509) .
•
Replace main PCB .
•
Replace lamp if it is disconnected .
(120V / 40W)
•
Smell or smoke from the burning dirt in
the oven might be generated at the very
first operation.
•
Replace or repair Display PCB .
•
Replace or repair Display PCB .
•
Remove the cap of regulator and mount it
again upside down .
•
Replace the regulator .
•
Replace the NG injector nozzle to LP
injector nozzle .
(Basically LN injector nozzles are
mounted at production line)
•
Replace or repair Relay .
•
Replace or repair connector .
•
Replace or repair harness .
•
Replace or repair connector .
•
Replace main PCB .