Samsung NY58J9850WS Service Manual page 90

Slide in gas ranges
Hide thumbs Also See for NY58J9850WS:
Table of Contents

Advertisement

8. Reference
Checkpoints before service request (Continued)
SYMPTOM
Keypad is not properly
worked
Warming drawer is not
worked
Oven lamp is not
worked
Smell or smoke is
occurred during the
very first operation.
LED display is a little
dim or dark, so it
makes uncomfortable
to see .
There is no buzzer
beep sound while
keypad is being
touched .
Cooktop flame with LP
is extraordinary short .
Cooktop flame with LP
is extraordinary long
(with yellow flame)
Convection fan is
not rotated .
This document can not be used without Samsung's authorization.
DIAGNOSIS
Make sure that keypad cable on Display
PCB is in normal state .
Make sure connector (CN201) on Display
PCB or PCB pattern .
Check a relay(RY506) and a
terminal(T508) at warming drawer .
Measure whether resistance of warming
drawer heater is in normal extent or not .
Check the oven lamp's relay and
connector (CN501) .
Measure the resistance of both ends of
lamp terminal .
This is in normal state .
LED display is inferior .
Check the state of buzzer on main PCB
and whether PCB pattern has a short
circuit or has been open .
Check the cap of regulator .
Check the injector nozzle .
Check whether Convection fan relay on
main PCB and connector(CN501) is in
normal .
Make sure whether harness between
Connector on main PCB and Connector
(CN501) on main PCB is connected in
normal .
90
REMEDY
Replace the keypad in case that it is
loosen or disconnected .
Replace or repair the keypad in case
cable is loosen or disconnected .
Replace the terminal(T508) or relay
(RY506) .
Replace a main PCB .
Replace a warming drawer heater .
Replace or repair if the harness is loosen
or disconnected .
Replace oven relay(RY509) .
Replace main PCB .
Replace lamp if it is disconnected .
(120V / 40W)
Smell or smoke from the burning dirt in
the oven might be generated at the very
first operation.
Replace or repair Display PCB .
Replace or repair Display PCB .
Remove the cap of regulator and mount it
again upside down .
Replace the regulator .
Replace the NG injector nozzle to LP
injector nozzle .
(Basically LN injector nozzles are
mounted at production line)
Replace or repair Relay .
Replace or repair connector .
Replace or repair harness .
Replace or repair connector .
Replace main PCB .