Reference; Checkpoints Before Service Request - Samsung NY58J9850WS Service Manual

Slide in gas ranges
Hide thumbs Also See for NY58J9850WS:
Table of Contents

Advertisement

8. Reference

8. Reference

8-1 Checkpoints before service request

SYMPTOM
Oven is not operated
(No power, No display)
Cooktop is not worked
(Ignition fault)
Oven temperature
is risen slowly
Oven temperature
is risen fast
The self-cleaning
feature will not operate
when warming drawer
is on .
This document can not be used without Samsung's authorization.
DIAGNOSIS
Measure an input voltage .
(L1-N, L2-N : 120V, L1-L2 : 240V)
Measure an input voltage of power cord
housing .
Measure voltage of connector(CN101)
on main PCB L1~N : 120V
Make sure that the relay on main PCB
is properly worked .
Measure voltage regulator(IC102) on
main PCB .
- IC102 : 7812A(DC 12V)
Measure voltage regulator(IC103) on
main PCB .
- IC103 : 7805A(DC 5V)
Check whether valve of gas line is
opened .
Check whether ignition spark is generated
from the electrode .
Make sure whether harness is connected
with Broil, Bake and convection heater
has been loosen or disconnected .
Make sure whether Broil, Bake,
and convection heater has been
disconnected .
Make sure that heater relay and pattern
on assy display .
Check whether harness has been
misconnected or have a short circuit .
Measure resistance values of each
heater are within a normal extent or
not .
This is in normal state .
89
REMEDY
Check circuit breaker .
Make sure that the state of wire is
connected with power cord housing .
Replace or repair if harness is loosen
or disconnected .
Check the harness is inserted into the
relay on sub PCB .
Replace or repair harness .
Replace main PCB .
Replace or repair harness .
Replace or repair main PCB .
Make sure that valve is opened .
Make sure that terminal of electrode is
connected to the spark module .
Replace the electrode . (in case of
broken electrode or cut-off wire)
Replace the spark module .
Repair and replace harness .
After taking out terminal from each heater,
measure resistance of heater and then
replace that if it is not a normal resistance
value .
Replace or repair relay .
Replace or repair assy display .
Replace or repair harness .
Replace heater is in a abnormal state .
The self-cleaning feature will not operate
when warming drawer is on .

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents