10-100 Fuser Temperature (Open) RAP
BSD-ON:BSD 1
The temperature of the Fuser is outside of the normal operating range of 383°F ± 5°F (195°C ±
5°C.)
Initial Actions
Switch off, then switch on the machine.
Procedure
Do not handle the fuser components until they have cooled. Some fuser components
operate at hot temperatures and can produce serious personal injury if touched.
DANGER: Ne pas manipuler les éléments du four avant de les laisser refroidir. Certains
éléments du four fonctionnent à des températures très élevées et peuvent causer de
graves blessures s'ils sont touchés.
AVVERTENZA: Non maneggiare i componenti del fusore finché non sono raffreddati.
Alcuni di questi componenti funzionano ad alte temperature e possono provocare gravi
ferite se vengono toccati.
VORSICHT: Die Fixieranlage sollte erst gehandhabt werden, wenn diese genügend
abgekühlt ist. Einige Teile der Fixieranlage erzeugen übermäßige Hitze und führen bei
der Berührung zu schweren Verbrennungen.
AVISO: No manipule los componentes del fusor antes de que se enfríen. Algunos de los
componentes del fusor funcionan a altas temperaturas y pueden ocasionar daños per-
sonales graves si se los toca.
Switch off the machine, then verify the Fuser is fully seated,
nections are OK.
Y
N
Check the Fuser connections for contamination and clean as required.
Firmly reconnect the Fuser Module. Switch the power on,
Check for +3.3 VDC to the Thermistor on Main PWB. The voltage is present.
Y
N
Check the wire harness for open or short circuits.
Install a new Main PWB,
PL 1.1 Item
Check the voltage to the Over Heat Thermostat. The voltage is present.
Y
N
Check for AC line voltage to the LVPS PWB,
Check the Over Heat thermostat for contamination.
Check the wire harness from the LVPS PWB for open or short circuits.
Install a new LVPS PWB,
PL 4.4 Item
Check the circuits and connectors for the Fuser Module.
Check the Heat Lamp for an open circuit.
Install a new Fuser Module,
PL 5.1 Item
Status Indicator RAPs
10-100 , 10-200/ 300
WARNING
PL 5.1 Item
26. The Fuser con-
7.
PL 4.4 Item
3.
3.
26.
10-200/ 300 Fuser Under/ Over Temperature RAP
BSD-ON:BSD 1
The temperature of the Fuser is outside of the normal operating range of 383°F ± 5°F (195°C ±
5°C.)
Initial Actions
Switch off the machine. Remove and reinstall the Fuser Assembly. Switch On the power.
Procedure
Do not handle the fuser components until they have cooled. Some fuser components
operate at hot temperatures and can produce serious personal injury if touched.
DANGER: Ne pas manipuler les éléments du four avant de les laisser refroidir. Certains
éléments du four fonctionnent à des températures très élevées et peuvent causer de
graves blessures s'ils sont touchés.
AVVERTENZA: Non maneggiare i componenti del fusore finché non sono raffreddati.
Alcuni di questi componenti funzionano ad alte temperature e possono provocare gravi
ferite se vengono toccati.
VORSICHT: Die Fixieranlage sollte erst gehandhabt werden, wenn diese genügend
abgekühlt ist. Einige Teile der Fixieranlage erzeugen übermäßige Hitze und führen bei
der Berührung zu schweren Verbrennungen.
AVISO: No manipule los componentes del fusor antes de que se enfríen. Algunos de los
componentes del fusor funcionan a altas temperaturas y pueden ocasionar daños per-
sonales graves si se los toca.
1.
If problem is intermittent, check the circuit of the Fuser Module for one of the following:
All connectors are securely connected and no contamination is present.
Short circuit or damaged wire, repair as necessary.
2.
Install a new Fuser Module,