M/T-Bd (Maintenance/Test Circuit Pack) - Avaya S8700 Maintenance Manual

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

M/T-BD (Maintenance/Test Circuit Pack)

M/T-BD (Maintenance/Test Circuit
Pack)
MO's Name As
It Appears in
Alarm
Alarm Log
Level
M/T-BD
MINOR
M/T-BD
WARNING
1.
UU is the universal cabinet number (1–64 for ATM PNC, 1–44 for CSS PNC). C is the carrier designation (A,
B, C, D, or E). SS is the number of the slot where the circuit pack resides (01–21).
The Maintenance/Test circuit pack supports packet-bus fault detection and bus
reconfiguration for the port network where it is installed. The circuit pack also
provides Analog Trunk testing, and data loop-back testing of DCP Mode 2
endpoints and Digital (ISDN) Trunk facilities via the TDM bus.
Port 1 of the Maintenance/Test board is the Analog Test port which provides the
Analog Trunk testing function for Automatic Transmission Measurement System
(ATMS). ATMS is a feature in which calls are made from a device called an
Originating Test Line (OTL) over a specific trunk to a device called a Terminating
Test Line (TTL). The OTL and TTL can then send tones over the trunk under test
and determine the quality of the connection. Ports 2 and 3 are the digital ports
which provide the digital (ISDN) trunk-testing functions. Port 4 is the packet port
which provides the packet-bus maintenance function.
See
''XXX-BD (Common Port Circuit Pack)'' on page 8-1872
errors. See also, related maintenance/test information for analog, digital, and
packet-bus ports:
M/T-ANA (Maintenance/Test analog port)
M/T-DIG (Maintenance/Test digital port)
M/T-PKT (Maintenance/Test packet-bus port)
Every port except the analog port (Port 1) of the Maintenance/Test board is
automatically administered when the circuit pack is inserted into the system and
automatically removed when the circuit pack is unplugged from the system. The
Analog port however, is administered via the station screen with the type "105TL"
for an OTL or a TTL. This port remains administered even after the circuit pack is
physically removed from the system. Care should be taken to remove the OTL or
the TTL before unplugging the circuit pack.
555-233-143