3. We recommend removing the MIG torch when the Spool Gun is connected to avoid accidental
arcing. Loosen the wing nut retaining bolt and slide the MIG torch out of the front of the machine.
Disconnect the 5-Pin trigger connection on the front of the machine.
4. Carefully slide the gas connector and the weld power connection through the weld cable access
opening in the front of the machine (Figure 10).
Weld Cable
Access
Opening
5. Open the wire compartment door.
6. Connect the gas connection quick connector to the gas connector (1) on the back panel of the
wire compartment.
7. Connect the weld power connection to the bolt on the top of the MIG connector (2).
8. Connect the 5-Pin trigger connector to the 5-Pin receptacle on the front of the machine (3).
9. See step 11 of WIRE FEED WELDING SET-UP in the Operating Instructions section.
Figure 9
Figure 10