Sensor statistics
Index
Subindex
Name
2001
01
Running time (s)
02
Total distance traveled (cm)
03
Total reversals
04
Min supply voltage (mV)
05
Max supply voltage (mV)
06
Min temperature (C)
07
Max temperature (C)
08
Max shock (G)
09
Supply violations (ms)
Table 8: The sensor statistics
Sensor statistics
Index
Subindex
Name
6010
01...1E
Preset for 1...30 magnets
650C
01...1E
Offset for 1...30 magnets
Table 9: Preset and offset
Attribute
Data type
Description
RO
Unsigned32
Total operational time of the sensor in seconds
RO
Unsigned32
Odometer: Total distance traveled by the position magnet in cm
RO
Unsigned32
Magnet cycles: Total number of directional changes by the magnet
RO
Unsigned32
Minimum input voltage so far in mV
RO
Unsigned32
Maximum input voltage so far in mV
RO
Signed16
Minimum temperature inside the sensor electronics housing so far in °C
RO
Signed16
Maximum temperature inside the sensor electronics housing so far in °C
RO
Unsigned32
Maximum shock so far measured by the integrated accelerometer
Note: Only available if the sensor is equipped with the optional accelerometer (for future
use).
RO
Unsigned32
Input Voltage out of range: Duration of exceeding or falling below the permissible power
supply range
Attribute
Data type
Description
RW
Unsigned32
With the preset, a value is entered for the current position which is to be output at this
position in the future. The difference between the entered value and the currently measured
position is calculated as an offset. The preset can be set for up to 30 magnets.
RW
Unsigned32
The difference between the entered position value and the currently measured position is
calculated as an offset.
I 39 I
R-Series V EtherCAT
Temposonics
®
Operation Manual
®
Need help?