IBM R/S6000 7012 300 Series Operator's Manual page 139

Table of Contents

Advertisement

c03
c04
c05
c06
c07
c08
c09
c20
c21
c22
c24
c25
c26
c29
c31
c32
c33
c34
c40
c41
c42
c43
c44
c45
c46
c47
c48
c49
c50
c51
c52
c53
c54
c55
c56
c57
c58
c59
c61
c62
c63
c64
c70
c99
B-12
Operator Guide
The wrong diskette is in diskette drive.
The loading stopped with a nonrecoverable error.
A diskette error occurred.
The rc.boot configuration shell script is unable to determine type of boot.
Insert the next diagnostic diskette.
RAM file system started incorrectly.
The diskette drive is reading or writing a diskette.
An unexpected halt occurred, and the system is configured to enter the
kernel debug program instead of entering a system dump.
The ifconfig command was unable to configure the network for the client
network host.
The tftp command was unable to read client's ClientHostName .info file
during a client network boot.
Unable to read client's ClientHostName .info file during a client network
boot.
Client did not mount remote miniroot during network install.
Client did not mount the /usr file system during the network boot.
The system was unable to configure the network device.
Select the console display for the diagnostics. To select No console display,
set the key mode switch to Normal then to Service. The diagnostic
programs will then load and run the diagnostics automatically.
A direct-attached display (HFT) was selected.
A tty terminal attached to serial ports S1 or S2 was selected.
A file was selected. The console messages store in a file.
Configuration files are being restored.
Could not determine the boot type or device.
Extracting data files from diskette.
Cannot access the boot/install tape.
Initializing installation database with target disk information.
Cannot configure the console.
Normal installation processing.
Could not create a physical volume identifier (PVID) on disk.
Prompting you for input.
Could not create or form the JFS log.
Creating root volume group on target disks.
No paging devices were found.
Changing from RAM environment to disk environment.
Not enough space in the /tmp directory to do a preservation installation.
Installing either BOS or additional packages.
Could not remove the specified logical volume in a preservation installation.
Running user-defined customization.
Failure to restore BOS.
Displaying message to turn the key.
Could not copy either device special files, device ODM, or volume group
information from RAM to disk.
Failed to create the boot image.
Loading platform dependent debug files.
Loading platform dependent data files.
Failed to load platform dependent data files.
Problem Mounting diagnostic CDROM disc.
Diagnostics have completed. This code is only used when there is no
console.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents