IBM R/S6000 7012 300 Series Operator's Manual page 105

Table of Contents

Advertisement

Step 13
(From Step 12)
The system checkout option checks all of the resources (available in standalone mode only).
Select and run the diagnostic tests on the resources you are having problems with or run
system checkout to check all of the configured resources. Find the response in the following
table and perform the specific action.
Diagnostic Response
An SRN is displayed.
The system stopped with a number
displayed in the 3-digit display.
The TESTING COMPLETE menu and the
No trouble was found message is
displayed, and you have not tested all of
the resources.
The TESTING COMPLETE menu and the
No trouble was found message
displayed and you have tested all of the
resources.
Step 14
(From Steps 12, 13)
A flashing 888 in the 3-digit display indicates that a crash message or a diagnostic
message is ready to be read.
1. Use the steps in the "Reading Flashing 888 Numbers" in Chapter 3 to:
Read all of the message.
Identify the SRN.
Record the remaining numbers for the service representative.
2. Record the SRN.
3. Report the SRN to the service organization. Report any other numbers to the service
representative to determine the location of the failing FRU.
4. STOP. You have completed these procedures.
6-10
Operator Guide
Action
Go to Step 15.
Go to Step 14.
Press Enter and continue with the testing.
Go to Step 19.
Notes: If dials and LPFKs are attached to
serial ports S1 or S2 and you are running
diagnostics from disk or server, the dials
and LPFKs will only appear on the
selection screen if they have been
configured by the user. Use the Dials and
LPFKs Configuration service aid to
configure these devices.
If the dials and LPFKs are attached to
serial ports S1 or S2, you must configure
them using the Dials and LPFKs
Configuration service aid before they can
be tested from diskette.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents