Fire Suppression Systems; General Description; Automatic Operation; Manual Operation - Broaster VF-2 Installation & Operation Manual

Ventless fryer
Table of Contents

Advertisement

GENERAL DESCRIPTION

The Fire Suppression system is specifically
designed for controlling wet chemical fires
in the fryer.
The system consists of a cylinder assembly
(with pressure switch and gauge), actuating
lever, fusible link assembly, manual pull sta-
tion and two nozzles.

AUTOMATIC OPERATION

Upon the detection of a fire, the system will
automatically operate. the fusible link in the
cooking area separates at a temperature of
280° F, which allows the spring to pull down
on the actuating lever. The valve stem is
pushed down releasing pressure and wet
chemical to the nozzles.

MANUAL OPERATION

When the manual pull handle on the front
panel is pulled, the system operates simi-
larly by disconnecting the fusible link cable
from the actuating lever. The spring pulls
down on the lever releasing pressure and
wet chemical to the nozzles.
7 -FIRE SUPPRESSION SYSTEM
IMPORTANT:
The manual pull
handle is to be
pulled ONLY IN
CASE OF FIRE in
the fryer (use
when the auto-
matic system
has
failed).
broaster.com Manual #16421 5/06 Rev 4/14
the pressure switch opens, deactivating the
power relay cutting all power to the fryer.
INSPECTION & MAINTENANCE
are detailed in Section 4, Fire Suppression
Maintenance and Replacement of the VF-2/
VF-3i Service & Parts Manual.
The Fire Suppression system must be ser-
viced on a regular basis. Three types of ser-
vicing are required: Monthly, Semi-Annualy,
and 12 Year. Prior to any inspection, the Fire
Suppression system needs to be exposed.

Gaining Access

To gain access to the Fire Suppression sys-
tem remove Electrical Control Access
Panel.
1. Disconnect main power.
2. Remove retaining screw.
3. Slide the panel up to clear retaining
tabs.
4. Pull the bottom toward the outside of
the unit.
7-1
If the pressure in the cylin-
der drops below 195 psi,
Selected fire suppression
maintenance procedures

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vf3i

Table of Contents