28. Access Door Switch: Indicates
whether Access Door is open. Unit will
not function if door is open. (on other
side of panel)
29. Fire Extinguisher: Capable of extin-
guishing a grease fire.
30. Fire Extinguisher Pressure Switch:
Monitors pressure within Fire Extin-
guisher. Unit will not operate if pres-
sure drops below specified minimum.
31. High Limit Reset: Resets the High
Limit Control when it trips to prevent
the oil temperature from exceeding
475F. (This may trip inadvertantly dur-
ing shipping.)
32. Fire Suppression Arming Pin: When
removed from Fire Extinguisher the
Fire Suppression system is armed to
activate when the Fusible Link is
melted.
33. Element Switch: Indicates that ele-
ment is up. Unit will not function if ele-
ment is up.
25
34. Air Filter Differential Pressure Switch:
35. Platform Lift Motor and Cam: Raises
36. Platform Down Switch: Senses that
37. Platform Up/Down Switch: Stops
38. Grease Filter Switch: Indicates when
4-3
broaster.com Manual #16421 5/06 Rev 4/14
28
31
34
27
30
32
29
36
37
Indicates an unacceptable level of air
flow through the Air Filter by measuring
pressure drop through filter. If pressure
drop exceeds maximum set value, unit
will not function.
Replace Air Filter every 3
months or sooner if
needed.
and lowers Platform.
platform is down.
motor when platform is up or down.
grease filter is not properly installed.
Unit will not run with grease filter not
properly installed.