the unit must be at least 20 cm from the nearest power source. Sockets/power sources must
be freely accessible at all times and comply with the following specifications: 220–240 V AC ~,
50/60 Hz, 16 A with 16 A fuse. No other loads may be connected to this power source.
14. The radiant heater must not be installed in close vicinity to bathtubes, showers or pools
nor in rooms where there is permanent high humidity. The distance to the bathtub or shower
AU
must be at least 100 cm and the distance to the pool at least 200 cm. A person standing in the
bathtube, shower or pool should never reach the switch or controller of the heater. If the HEAT-
SCOPE
is installed in such an environment with high humidity, the switches or other operating
®
components must be positioned in such a way that they cannot be touched by persons who are
in direct contact with water. When a radiant heater is installed in a bathroom, the CE standard
requires that at least one heating element visibly „glows" as soon as the unit is switched on.
15. The heater must not be installed nor operated in environments containing chlorine (like
inside pool areas) or salt (like near the coast).
16. Disconnect the radiant heater from the power supply before cleaning it, adjusting the angle
or removing it from the wall/ceiling. Wait until the heating elements are not glowing any more
and the housing is noticably cooled down. If buried cables are used, switch off the power using
an omnipolar switch. Wait at least 30 minutes after the last use before you start cleaning it. All
surfaces should be cleaned using a damp cloth only. Never use cleaning products containing
alkaline substances such as sodium hydroxide or soap, surfactants or solvents such as alcohol.
Use only a very soft cloth or a brush for the reflector and the heating elements.
17. Always remember to switch off the unit after use.