HeAtSCoPe
ViSion and SPot – Wiring / Connecting regulation
®
Pillar terminal 1000 K / 3 + 4 mDS Ht 0,5–6 mm², 3 + 4 pol.: (1) Wire protection with pin-in-hole protection for stripped litz
wires and litz wires with cable end sleeves, (2) Tighten screws with 0.5 Nm, (3) Wiring / Connection Version 2, shortened litz
wire 1–2.5 mm
, stripped 6–7mm, (4) Wiring / Connection Version 1, standard litz wire 1–2.5 mm
2
4 mm
T 105 °C – VDE, UL, CSA
inadmissable, defective, and dangerous wirings / connections
(1) terminal is tightened too strong, (2) isolation errors and missing air and creepage distances, (3) different wirings are seized in
one terminal, (4) too many conductors in one terminal, (5) terminal tightened over isolation, (6) dangerous twirling of litz wires by
hand, (7) no pressing signs of a safe terminal connection at wiring, (8) twirling of litz wires by hand with isolation tape
(1)
(5)
(1)
(3)
X
(2)
X
(6)
Tel.: +61 2 9997 3050 · info@mad-australia.com · www.mad-australia.com
X
(3)
X
(7)
A M B I E N T H E A T I N G S O L U T I O N S
, with cable end sleeve
2
(2)
(4)
4 mm
T 105 °C – VDE, UL, CSA
X
(4)
X
(8)
AU
X
X