like rain and dust from above; so the HEATSCOPE
has to be installed under a roof, an overhang or in
®
combionation with the optional available weather shield.
Acc. to EU 2015/1188 ecodesign directive for energy-related products the application of a thermos-
tat with a room sensor, weekday control system and window opening detection is mandatory, when
installation a heating unit indoors. This is only possible with the HEATSCOPE
model types VE and SM. In
®
combination with the optional available thermostat DEVIreg™ Smart the heaters of these series fulfill the
AU
conformity of the ecodesign directive.
HEATSCOPE
heaters are basically made for outdoor use – and most cases they are used outdoors
®
finally. Due to this they are factory-set delivered without any thermostat control system acc. to EU
2015/1188 ecodesign directive. This is consequent, reasonable and will economise valuable ressources.
Many times a separate temperature system / thermostat acc. to ecodesign directive is already installed
and the heaters should be fit in this system. In this case the customer or the assigned installer is respon-
sible to accomplish the EU standards of the ecodesign directive.
operation, installation instructions and minimum distances
Once you have installed the unit, you can use it for the first time.
The HEATSCOPE
features an omnipolar „ON/OFF" switch. You can control the radiant heater manually
®
using a selector switch on the unit itself or using an IR remote control which comes supplied (depending
on the model). The unit must be connected to a residual current circuit breaker and a fuse!
Install the unit only in indoor or outdoor areas that are well protected from any weather influences from
above like rain and dust. The heater is protected from lateral spray water, but it has to be covered with a
roof or a similar canopy like the optional available weather shield upwards.
CAUTION: The mounting of the heater on the wall and on the cieling as well as in glass houses and con-
servatories has professionally to be accomplished solely according to the mounting regulations. Specified
safety distances given are min. values and may deviate from the local building and fire safety regulations.
The safety distances as well as the local building and fire safety regulations must be complied with at all
times, leave inproper stated installation settings undone at any time. Deviant installation settings require
the technical approval of the manufacturer, who can prescribe the installation of temperature and wea-
ther protection shields. In the case of a deviant installation setting without approval of the manufacturer
danger for people and environment occurs. Warranty and guarantee expires for all heaters, which are not
installed according to this operation and installation manual!
Other protective measures may need to be taken in accordance with local fire safety regulations, e.g. for
installation on cumbustible surfaces.
All cables must be positioned so that they cannot come into contact with the radiant heater at any time.
The radiant heater must not be installed directly below a power socket. The sides of the HEATSCOPE
®
must be at least 20 cm from any power sockets.
Care, maintenance and service
Before cleaning and maintaining your HEATSCOPE
, disconnect it from the power supply or, if buried
®
cables are used, switch it off via the omnipolar switch. Ensure that the unit has cooled down – wait at
least 30 minutes after the last use before you start cleaning it.
Tel.: +61 2 9997 3050 · info@mad-australia.com · www.mad-australia.com

Advertisement

Table of Contents
loading

Table of Contents