Heatscope MHS-SM1600 Original Installation And Instruction Manual page 23

Electric ambient carbon radiant heater for indoor and outdoor areas
Table of Contents

Advertisement

inStAllAtion reGUlAtionS for mHS HeAtSCoPe
Professional and safe installation of HeAtSCoPe
Standards:
All MHS HEATSCOPE
EN / IEC 60335-1 and EN / IEC 60335-2-30 (Household and similar electrical appliances Safety)
installation:
Installation of heaters must be done acc. to installation guideline of the ORIGINAL HEATSCOPE
INSTRUCTION MANUAL. Min. distance between the two mounting brackets on back of the heater as designated, min.
installation height: 1.8 m from ground, min. distances to walls, ceilings or other materials as designated in the manual.
Installation on a ceiling should reach a min. distance of 2.2 m from ground to avoid any contact with hair, head, or skin.
Despite IP X4 protection the heater should be installed well covered against rain and direct water impacts to guard the
high end reflector shields and protect their full functionality.
Attention!
Inadequate derivation of heat will cut off the lower heating element shortly after activation. After some time of cooling
down this heating element will power up again. Inappropriate installation and inadequate derivation may overload the
heater. For safety reasons a temperature limiter is installed, which cuts off the upper heating element permanently
due to inappropriate installation or incorrect electrical connection – until electrical connection is disconnected and
the heating element is totally cooled down. In case the heater is damaged by inproper installation or by a missing heat
derivation, the manufacturer's guarantee will no longer be applicable.
Professional and safe electrical connection of HeAtSCoPe
Standards:
The electrical installation must be done by a professional electrician acc. to DIN VDE 0298-4 / IEC 60364-5-52, current
load of electrical wirings / connections acc. to DIN VDE 0113-1 / EN 60204-1 for long-term usage with environmen-
tal temperatures of 40° C, with conversion factor for higher environmental and wiring / connection temperatures,
accumulation of wirings or connections for the same type of installtion and max. wiring / connection lengths acc. to DIN
VDE 0100-520 Blt. 2 / EN 60204-1. Due to the listed impacts on wiring / connection longer wirings / connections from
distribution board to cable of heater should be constructed one cross section higher (cf. table below). Connection of
supply cable and heater cable should only be done with tested pillar terminals with wire protection and central fence.
example: ADELS 1000K 3 or 4 MDS HT 0,5 - 6 mm², 40 Amp. Testing Signs: VDE, UL, CSA, KEMA, SEMKO, FI (cf. table)
Attention!
MHS HEATSCOPE
wiring / connection cross sections and inadequate connections of supply and heater cables may cause contact resis-
tances, which will boost significantly during operation. In general inadmissable high temperatures will occur at contacts
of switches, on the electrical board, and at contacts of the heating elements, which may cause damage of switches,
melting of contacts, damage of heating elements and melting of isolation of wiring. In case the heater is damaged by
inproper installation or by a missing heat derivation, the manufacturer's guarantee will no longer be applicable.
table 1: Cross section of wiring / connection and fuse from supply to heater
considering longer wiring /connections and environmental temperatures
per 1 piece HeAtSCoPe
heater
®
VT1600 + SP1600: 220-240 VAC, 7,0 A:
VE1600 + SM1600: 220-240 VAC, 7,0 A:
VT2200 + SP2200: 220-240 VAC, 9,6 A:
VE2200 + SM2200: 220-240 VAC, 9,6 A:
SP2800: 220-240 VAC, 12,2 A:
SM2800: 220-240 VAC, 12,2 A:
VT3200: 220-240 VAC, 13,9 A:
VE3200: 220-240 VAC, 13,9 A:
per 2 pieces HeAtSCoPe
®
VT1600 + SP1600: 220-240 VAC, 7,0 A:
VE1600 + SM1600: 220-240 VAC, 7,0 A:
ViSion and SPot heaters acc. to int. standards:
®
VISION and SPOT infrared design heaters are designed, developed and manufactured acc. to
®
ViSion and SPot heaters acc. to int. standards:
®
heaters are working in high power levels of 1600 W up to 3200 W (= 7 A up to 14 A). Inappropriate
®
heater cable
connecting terminal 3 / 4 core
3 x 1,5 mm²
1000 K / 3 MDS HT 0,5-6,0 mm²
4 x 1,5 mm²
1000 K / 4 MDS HT 0,5-6,0 mm²
3 x 1,5 mm²
1000 K / 3 MDS HT 0,5-6,0 mm²
4 x 1,5 mm²
1000 K / 4 MDS HT 0,5-6,0 mm²
3 x 1,5 mm²
1000 K / 3 MDS HT 0,5-6,0 mm²
4 x 1,5 mm²
1000 K / 4 MDS HT 0,5-6,0 mm²
3 x 1,5 mm²
1000 K / 3 MDS HT 0,5-6,0 mm²
4 x 1,5 mm²
1000 K / 4 MDS HT 0,5-6,0 mm²
heater
heater cable
connecting terminal 3 / 4 core
3 x 1,5 mm²
1000 K / 3 MDS HT 0,5-6,0 mm²
4 x 1,5 mm²
1000 K / 4 MDS HT 0,5-6,0 mm²
Tel.: +61 2 9997 3050 · info@mad-australia.com · www.mad-australia.com
A M B I E N T H E A T I N G S O L U T I O N S
ViSion AnD SPot infrAreD HeAterS
®
1 connection from
heater cable to
DIN VDE 0100-520
Blt. 2 / EN 60204-1
1 connection from
heater cable to
DIN VDE 0100-520
Blt. 2 / EN 60204-1
INSTALLATION AND
®
fuse
cupply
DIN VDE 0100-520
Blt. 2 / EN 60204-1
fuse
cupply
DIN VDE 0100-520
Blt. 2 / EN 60204-1
AU

Advertisement

Table of Contents
loading