only be replaced by a professional servicing company enlisted by the manufacturer.
The supply cable must be connected generally in a commercially available wet room distribution
box with IP65 protection class acc. to IEC or UL / CSA (not within the scope of supply).
3. The HEATSCOPE
is protected against splashing water and has an IP44 protection class ra-
®
ting (model VISION) resp. IP24 (model SPOT). Nevertheless, it is mandatory to install the unit on
a surface where it is well protected from any weather influences like rain and dust from above;
so the HEATSCOPE
has to be installed under a roof, an overhang or in combionation with the
®
optional available weather shield.
4. As soon as the unit is connected to a power source and switched on using an „ON/OFF"
switch or other operating component, it takes a maximum of 15-30 seconds until it reaches its
operating temperature.
5. CAUTION: Risk of burns! The front screen (approx. 300°C) and protective fin front (approx.
400°C) gets very hot when the unit is operating.
Do not cover either part of the front or the entire front of the radiant heater. Do not touch any
part of the HEATSCOPE
6. For your own safety, never dry textiles or other materials using the HEATSCOPE
radiant heater may result in a fire! Always maintain a distance from the heating surface of the
HEATSCOPE
of at least 150 cm from textiles, cloth and other easy inflammable soft materials.
®
7. Ensure that cables, furniture, flammable materials or other objects do not come into contact
with the surface of the radiant heater and never cover the unit. Under no circumstances should
the unit be covered or enclosed with insulating or similar materials. Adequate ventilation sur-
rounding the heater must be ensured at any time. Ledgers, beams and rafters must not be cut
into or grooved to install the infrared heater.
When installing the HEATSCOPE
least 180 cm from the ground and the safety clearances from the wall and ceiling set out in this
manual are maintained. Always maintain a distance from the heating surface of the HEAT-
SCOPE
of at least 150 cm from textiles, cloth and other easy inflammable soft materials.
®
8. Disconnect the radiant heater from the power supply before cleaning it, adjusting the angle
or removing it from the wall/ceiling. Wait until the heating elements are not glowing any more
and the housing is noticably cooled down. If buried cables are used, switch off the power using
an omnipolar switch.
9. The HEATSCOPE
features an omnipolar „ON/OFF" switch. The unit can be controlled manu-
®
ally either using an IR remote control (supplied, depending on the model) or a selector switch
on the unit itself (depending on the model as well). The unit must be connected to a residual
current circuit breaker and a fuse on the installation side.
10. The unit must only be used with an approved isolating system, which must be built in the
existing electrical installation acc. to the facility regulations. The heater comes as standard with
a separate open-ended cable for connection purposes.
during operation and up to 30 minutes after switching it off.
®
radiant heater, ensure that the lower edge of the unit is at
®