9
Maintenance
9.3
Maintenance schedule
Test object
Proof of insulation
reliability in accordance
with DIN 57530 part 1 /
VDE 0530 section17.1
Maintenance
Replacing all wear parts
(bearings, seals,
operating fluids, etc.)
Summary
Confirmation
9.3.1

Classification

Table 26:
Classification
Classification
by safety profile
or by operating profile
Test run
Visual checks
Functional inspection
Extended test
Maintenance
68 / 75
Test interval according to classification
5 million switching cycles
Complete test passed
The test was performed in accordance with the manufacturer's maintenance manual.
Location/date
Low requirements
Applications in functions and
areas with low safety
requirements
Mainly at a standstill, operation
irregular and seldom
Every six months
Annually
Every 2-3 years
Recommendation:
Every 5 years
or after
Repair required
Company
Standard
Applications in functions and
areas with normal safety
requirements
Operated in average value
ranges of the permissible
operating data according to
type plate
Annually
Annually
Recommendation:
Every 5 years or after 5 million switching cycles
ELDRO-EdEx-Montageanleitung-607338-EN.docx
Test
Test
performed
passed
measured values
Tester
Signature
Higher requirements
Applications in functions and
areas with very high safety
requirements
Operated in limit value ranges
of the permissible operating
data according to type plate
Every six months
Annually
Every 2-3 years
Evaluation /
Next test