Electrical System; Voltage And Frequency; Operating Fluid - EMG ELDRO EdEx Series Assembly Manual

Electro-hydraulic lifting thruster
Table of Contents

Advertisement

3.7

Electrical system

3.7.1

Voltage and frequency

3.8

Operating fluid

Table 19:
Operating behaviour depending on the ambient temperature
Temperature range
-10 °C to +40 °C
-40 °C to +40 °C
-25 °C to +40 °C
-10 °C to +60 °C
ELDRO-EdEx-Montageanleitung-607338-EN.docx
All EdEx thrusters are switched to star (Y) when delivered.
Table 18:
Electrical voltage and frequency (basic version)
Name
Operating voltage
Voltage tolerance,
permissible
Frequency
Frequency tolerance,
permissible
The operating fluid used depends on the ambient temperatures at the
place of installation
Operating fluid
Hydrotherm 46 M
Xiameter PMX-200 Silicone Fluid 10 cst
Pentosin CHF 11S
Pentosin CHF 11S
Special operating fluids are required for other temperature ranges
(contact the manufacturer / ⇒ General chapter, Manufacturer
section).
Technical data
Electrical system
Values
3/N/PE AC 230 up to 690 V
3/N/PE AC 660/1140 V (HV)
±5 %
50 Hz or 60 Hz
±2 %
Water glycol base
for low temperature oil
Standard oil
for high temperature oil
3
3.7
Remark
33 / 75