6.3.2
Changing the set time and the reset time
6.4
Completing assembly
ELDRO-EdEx-Montageanleitung-607338-EN.docx
The integrated valve system allows the stepless extension of the
setting and/or resetting times. Adjustment takes place with a
regulating screw. The regulating screw is located inside the thruster
and is accessible after removing the outer screw plug. An Allen key (8
mm) is required as a tool. The setting times are listed in tabular form
in the technical data (⇒ Technical Data chapter, Setting times
section).
The setting range is 0 to 6 revolutions (0 = CLOSED = max.
delay). The factory setting is 3 revolutions (starting from the
zero position).
Unscrew screw plug
Turn the regulating screw to set the required set or reset time
Screw in screw plug
After completing assembly, check that the earthing conductor system
is consistent with a resistance meter.
Assembly and installation