Advertisement

6.3.2

Changing the set time and the reset time

6.4

Completing assembly

ELDRO-EdEx-Montageanleitung-607338-EN.docx
The integrated valve system allows the stepless extension of the
setting and/or resetting times. Adjustment takes place with a
regulating screw. The regulating screw is located inside the thruster
and is accessible after removing the outer screw plug. An Allen key (8
mm) is required as a tool. The setting times are listed in tabular form
in the technical data (⇒ Technical Data chapter, Setting times
section).
The setting range is 0 to 6 revolutions (0 = CLOSED = max.
delay). The factory setting is 3 revolutions (starting from the
zero position).
 Unscrew screw plug
 Turn the regulating screw to set the required set or reset time
 Screw in screw plug
After completing assembly, check that the earthing conductor system
is consistent with a resistance meter.
Assembly and installation
Completing assembly
6
6.4
55 / 75