Setting Times - EMG ELDRO EdEx Series Assembly Manual

Electro-hydraulic lifting thruster
Table of Contents

Advertisement

3
Technical data
3.5
Characteristics
3.5.3

Setting times

Table 15:
Time data of the lowering and resetting movement
EdEx type
EdEx 32/50...
EdEx 50/50...
EdEx 80/60...
EdEx 80/75...
EdEx 125/60...
EdEx 125/75...
EdEx 150/60...
EdEx 150/75...
EdEx 200/60...
EdEx 250/60...
EdEx 320/100...
EdEx 80/160...
EdEx 125/160...
EdEx 150/160...
EdEx 200/160...
EdEx 250/160...
EdEx 320/160...
30 / 75
The following table contains time data, the lowering and resetting
movement, determined for EdEx lifting thrusters without built-in
lowering valve with constant nominal weight loads at +20 °C thruster
temperature.
Without lowering valve
Lowering time
in [s]
0.45
0.36
0.48
0.62
0.36
0.49
0.34
0.44
0.40
0.35
0.60
0.90
0.70
0.65
0.85
0.80
0.62
Detailed data for the adjustable delays for installed lowering valves
must be determined by the manufacturer
through individual tests. This requires precise information regarding
the operating conditions.
With integrated lowering valve
Adjustable lowering time
min. in [s]
For data refer to delivery documents, consult with EMG
Automation GmbH if necessary
For data refer to delivery documents, consult with EMG
Automation GmbH if necessary
EMG Automation GmbH
ELDRO-EdEx-Montageanleitung-607338-EN.docx
max. in [s]