System; Beeper - Omega RD8800 User Manual

Table of Contents

Advertisement

Chapter 5 Programming
Refer to the modem manual for other modems. The modem needs to be set up as follows.
Operation
Modem Attention call
Load factory defaults
Ignore DTR line
Quiet, no response to DTE
Auto answer on the first ring
Set 9600 baud
No compression
No ARQ
Use profile 0 on wake up
Store settings into profile 0
Set V.34 modulation, no automode, 19200 bps
Set 19200 baud
The entire string may not fit in the display window. Use the LEFT (← ← ← ← ← ) or RIGHT (→ → → → → ) button to navigate through
the string. The modem string is then sent once you return to the Program menu or whenever power is applied
to the Recorder. Refer to Chapter 2.4 for modem connection.

5.11 System

The System menu option allows the user control the Beeper, set Passcodes or Alternate Languages, and configure
the Parallel Printer Port.
To modify this System parameters:
From the Program menu use the UP (↑ ↑ ↑ ↑ ↑ ) or DOWN (↓ ↓ ↓ ↓ ↓ ) button to highlight System and then
press the ENTER button. The System menu will be displayed as shown in Figure 5-9.
Use the UP (↑ ↑ ↑ ↑ ↑ ) or DOWN (↓ ↓ ↓ ↓ ↓ ) button to select the option you wish to program and then
press the ENTER button. The options are described in the following sections.

5.11.1 Beeper

The Beeper menu option allows the user to turn the Beeper On or Off. If On, the
Beeper provides audible feedback to button/key presses, indicates errors and beeps
on alarm condition.
To turn the Beeper On or Off:
From the System menu use the UP (↑ ↑ ↑ ↑ ↑ ) or DOWN (↓ ↓ ↓ ↓ ↓ ) button to highlight Beeper and then press the ENTER
button. The current Beeper status will be displayed as "Beeper=YES*" or "Beeper=NO*". Press the YES
button to turn the Beeper On, or the NO button to turn the Beeper Off and the press the ENTER to return to the
System menu.
5.11.2 Passcodes
The Passcodes menu option allows the user to program a Passcode to protect the FUNCtion menu and/or the
PROGram and Hidden menus from unauthorized changes. Once a Passcode is set, it must be entered to gain
access to the respective menu. Separate Passcodes can be set for either. Note that if a Passcode is forgotten,
you will not be able to change the configuration of the unit. The only way to change or delete a Passcode is to
know the present Passcode. Treat Passcodes with respect.
Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com
Rockwell etc.
US Robotics, etc
AT
&F
&D0
Q1
S0=1
S37=9
%C0
n/a
&Y0
&W0
+MS=11,0,19200
n/a
Page 5-47
AT
&F
&D0
Q1
S0=1
&U6&N6
&K0
&M0
Y0
&W0
n/a
&n10
Beeper
Passcodes
Alt. Language
Printer out
Figure 5-4
System Menu

Advertisement

Table of Contents
loading

Table of Contents