Figure 8 Trap Receivers - Tripp Lite SNMP Solo MT-SE-37/02 Owner's Manual

Tripp lite snmp owner's manual
Table of Contents

Advertisement

Figure 8 Trap Receivers

To set traps, at the prompt type:
Set, <space>, enter the number of the column from 1 through 4,
<space>, enter the IP address, <space>, severity code–1,2, or
3, and name of the community string. Press <enter>. The
severity level codes for messages are:
1
Informational
2
Warning
3
Severe
The trap receiver receives all assigned severity level messages
and the ones rated above. If you assign severity code 2, the
manager receives warning and severe levels.
A set trap example.
The top of the screen reflects your changes: