Cleanup and Storage

Cleaning the sprayer with warm water is
required after each use to remove any
disinfectants and residues from the sprayer.
Sufficient cleaning, followed by draining all
water from the system will ensure a trouble
free start up the next time the sprayer is used.
Use only water for cleaning.
Clean in a well-ventilated area. Keep a
good supply of fresh air moving through
the area.
To avoid serious injury or damage to
equipment, do not expose the sprayer
electronics to water. Keep sprayer at least
10 in. (25 cm) above the rim of the
container when cleaning.
Follow Static Grounding Instructions,
page 23, when using disinfectants with
alcohol active ingredients, or other
flammable disinfectants.
NOTICE
Disinfectant left in sprayer will damage the
sprayer. To avoid damage, always
completely flush with warm water after every
use. See Cleaning Sprayer, page 19. Do
not store sprayer with disinfectant in it.

Cleaning Sprayer

1.
Perform Pressure Relief Procedure,
page 10.
3A7649A
Cleanup and Storage
2.
Open the VacuValve to allow air into the
FlexLiner.
3.
Remove cup assembly from sprayer. Set
sprayer on a rag to capture any
disinfectant that may drip.
4.
Separate Cup Lid from Cup Support.
5.
Pour excess disinfectant into waste
bucket. Hold the FlexLiner in place when
pouring. Wipe excess disinfectant from
Cup Lid.
ti29721a
19