8.7 Auto-Dialer Connection (Separate purchase required)
The Auto-dialer function of this unit has not been evaluated by UL.
Connect the input wire of Auto-Dialer to TTL output, Orange with White stripe wire.
Connect (+) wire of Auto-Dialer to DC +12V (be sure that the existing power supply has enough
capacity to support this accessory or upgrade to a sufficient one.)
Connect (-) wire of Auto-Dialer to Power GND (-) wire.
Connect Telephone Line plug (RJ-14) to Auto-Dialer.
(If an active High Auto-Dialer is used, then see section 12-59 to change the TTL output
level from the defaulted setting.)
8.8 Wiegand Input Connection from Another Compatible Wiegand Reader
(Separate purchase required)
Connect (+) wire of Reader to DC +12V (be sure that the existing power supply has enough capacity
to support this accessory or upgrade to a sufficient one.)
Connect (-) wire of Reader to Power GND (-) wire.
Connect Wiegand output DATA0 wire of the additional Reader to DATA0, Pink wire.
Connect Wiegand output DATA1 wire of the additional Reader to DATA1, Cyan wire.
8.9 Chime Bell Connection (Separate purchase required)
Connect (+) wire of Chime Bell unit to Bell Output, Brown with White stripe wire of Main
Unit.
Connect(-) wire of Chime Bell unit to Power GND(-) wire.