8.4 Exit Button Connection
Connect one of the wires of Exit Button to Exit Button Input, Orange wire.
Connect the other wire of Exit Button to Power GND (-) wire.
(If a normally closed Exit button is used, then see section 12-55 to change the detection
scheme from the defaulted setting)
8.5 Door Contact Sensor Connection
Connect Door Contact sensor (COM) wire to Door Contact Input, Yellow with Red stripe wire.
Connect Door Contact sensor (NO) wire to Power GND (-) wire.
(If a normally closed Door Contact sensor is used, then see section 12-57 to change the detection
scheme from the defaulted setting.)
8.6 Auxiliary Input Device Connection (Applied to AUX Input #1, #2, #3)
Connect one wire of the Auxiliary Input Device to the AUX Input wire
(Input *1 Green, Input *2 Green with White stripe, Input *3 Green with Red stripe wire).
Connect the other wire of Auxiliary Input Device to Power GND (-) wire.
(If a normally closed input device is used, then see section 12-49, 51 & 53 to change the
detection schemes from the defaulted settings.)
Continued on next page.