10
MENU
SETTINGS
1. Check that the green power LED is on.
2. Press
. Press
3. Use the
or
4. Press
5. Press
or
arrow to scroll to "Password". The
default setting is "Disabled".
6. Press
7. Press
or
arrow to change the setting to
"Enabled". Press
8. Press the
arrow. "Password Timeout" will be
displayed. The factory default time is 1 minute. This
means the IntelliFlo
®
into Password Protection mode 1 minute after the
last control panel key is pressed.
9. Press
to change time setting from 1 minute
to 6 hours and press
10. Press the
arrow and then press
"Enter Password" to change the setting.
11. Press the
or
press the
or
number to desired setting.
12. Press
to save. To cancel any changes, press
to exit without saving.
1. Press any button (besides the speed button) to prompt
the screen for a password.
2. To enter password, use the
move the cursor and the
to scroll through the digit then press
INTELLIFLO
Variable Speed Pump Installation and User's Guide
®
to select "Settings".
arrow to scroll to "Device".
(450 RPM - 1700 RPM) - Default: 450 RPM
to save.
Variable Speed Pump will go
to save.
arrows to move cursor and
arrow to change the password
and
arrows to
and
arrow button
SPEED 1-8
The IntelliFlo
Variable Speed Pump can be pro-
®
grammed in three different modes:
be programmed in all three modes. Speeds 5-8 can
only be programmed in Schedule mode since there are
no buttons on the control panel for Speeds 5-8. The
default setting for Speeds 5-8 is "Disabled".
on
Speed Menu Tree Options
Assigns a speed to one of the four Speed buttons
on the control panel. This mode can only be used for
speeds 1-4.
To operate in Manual mode, press one of the four
speed buttons and then press the
The pump will run the assigned speed for that speed
button.
Speeds 1-4 can be programmed to run at a certain
speed and for a duration of time once a speed button
is pressed.
Speeds 3 and 4 are Egg Timers by default. If you
desire a different method of operation, speeds 3 and 4
can be changed to Manual mode in the control menu.
To operate in Egg Timer mode, press a speed but-
ton and then press
speed for the set amount of time and then turn off.
during a 24 hour period. Speeds programmed in
Schedule mode will override any manually selected
speed (speeds set by manually pressing any of the
speed buttons on the control panel).
. Speeds 1-4 can
button.
. The pump will run that