Pump Reassembly - Pentair INTELLIFLO Installation And User Manual

Variable speed pump
Table of Contents

Advertisement

22
1. When installing the replacement shaft seal, use
silicone sealant on the metal portion before pressing
into the seal plate as shown.
Use extreme care when applying sealant. Be
sure no sealant contacts the seal plate surface or
the ceramic seal. Allow sealant to cure overnight
before reassembling.
2. Before installing the rotating portion of the seal into
the impeller, be sure the impeller is clean. Use a
light density soap and water to lubricate the inside
of the seal. Press the seal into the impeller with
your thumbs and wipe off the ceramic and carbon
faces with a clean cloth.
3. Remount the seal plate to the motor.
4. Screw in the impeller lock screw (counterclockwise
to tighten).
5. Remount the diffuser onto the seal plate. Be sure the
plastic pins and holding screw inserts are aligned.
Ensure that the seal plate o-ring is clean
and free of debris.
6. Grease the diffuser o-ring and seal plate gasket
prior to reassembly.
7. Assemble the motor subassembly to the pump
housing by using the two (2) through bolts for proper
alignment. Do not tighten the through bolts until all
Ensure that the seal plate gasket is properly
seated inside of the pump assembly. The seal
gasket can be pinched between the seal plate and
the pump housing while tightening these six (6)
screws, preventing a proper seal and producing a
slow leak when the pump is restarted.
8. Reinstall the drive onto the top of the motor.
9. Fill the IntelliFlo
Variable Speed Pump with water.
®
INTELLIFLO
Variable Speed Pump Installation and User's Guide
®
10. Reinstall the pump lid and plastic clamp. See
"Cleaning the Pump Strainer Basket" on page 20
for details
11. Reconnect the RS-485 communication cable to
the pump.
12. Prime the pump; refer to "Priming the Pump" on
page 4.
1. Be sure all electrical breakers and switches are
turned off before removing the control panel.
2. Disconnect the RS-485 communication cable
from the pump.
3. Remove the four (4) Phillips head screws from the
outer corners of the drive top cover.
4. Unplug the keypad top cover from the drive and set
it to the side in a safe place.
5. Remove the three (3) Phillips head screws, located
inside the drive, that anchor the drive to the motor.
6. Lift up the drive assembly and remove it from the
motor adapter located on top of the motor assembly.
the drive and motor, it is critical in keeping moisture
out of the drive and motor. Replace the gasket if
damaged. Do not reassemble with a damaged or
missing gasket.
Pump Illustrated Parts View
Be careful not to remove the gasket between

Hide quick links:

Advertisement

Table of Contents
loading