MENU
Pump Menu: Settings
SETTINGS

Password Protection

The default setting for password protection is disabled.
When this feature is enabled, the pump display will prompt
for the password before allowing access to the control
panel and buttons.
The entered password is any combination of four (4)
digits.
• The pump can always be stopped by pressing Start/
Stop, even when password protection is enabled.
• If the pump is stopped, the pump cannot be turned
back on with Start/Stop while running in manual mode.
• Pressing Start/Stop when the pump is off will return it
back to the Running Cycles Mode and run at the next
scheduled run time. If the present time is within the
scheduled run time, the pump will run the scheduled
speed.
• All functions including
programming are
disabled in Password
Protection Mode.
• Screen will read "Enter
Password" if any button
other than the Start/
Stop button is pressed
• Key icon displayed
in the upper left side
of the screen when
Password Protection
is on.

Setting Password

1. Check that the green power LED is on.
2. Press Menu. Press Select to select "Settings".
3. Use the Up or Down arrow to scroll to "Device".
Press Select.
4. Press Up or Down arrow to scroll to "Password".
Press Select.
5.
The default setting is "Disabled". Press Up or Down
arrow to change the setting to "Enabled". Press Save
to save.
6. Press the Down arrow. "Password Timeout" will be
displayed. The factory default time is 1 hour. This
means the IntelliFloXF
Pump will go into Password Protection mode 1 hour
after the last control panel key is pressed.
7. Press Select to enter edit mode. Use the Up or Down
arrow to edit the time setting from 1 minute to 6 hours
and press Save to save setting.
8. Press the Down arrow and then press Select on
"Set Password" to change the setting.
Password
Protection
Enabled
12:15p
750 RPM
750 RPM
150 Watts
Running Speed 1
®
VSF Variable Speed and Flow
XF
®
INTELLIFLO
and INTELLIPRO
9. Press the Left or Right arrows to move cursor and
press the Up or Down arrow to change the password
number to desired setting.
10. Press Save to save. To cancel any changes, press
Back to exit without saving.
Entering Password
1. Press any button (besides the program buttons) to
prompt the screen for a password.
2. To enter password, use the Left and Right arrows to
move the cursor and the Up and Down arrow button
to scroll through the digit then press Save to confirm.

Set Ramping Rate

The rate that the drive changes the motor speed
can be reduced for smoother operation. This setting
increases or decreases how quickly the pump can
ramp up or down between two speeds. Rates can be
set and adjusted for ramping up and ramping down
individually.
If the Start/Stop button is ever pressed, the motor will
immediately stop and will not follow the programmed
ramping rate. The default setting is Fast, which is the
traditional IntelliFloXF ramping rate. Medium will take
twice as long to change speeds, and Slow will take
three times as long.
To Set Ramping Rate:
1. Check that the green power LED is on.
2. Press Menu.
3. Press Select to select "Settings".
4. Use the Up or Down arrow to scroll to "Device".
Press Select.
5. Use the Up or Down arrow to scroll to "Ramping".
Press Select.
6. Use the Up or Down arrow to scroll to "Ramp Up".
Press Select and use the Up or Down arrow to
choose between "Fast", Medium or "Slow". Press
Save.
7. Use the Up or Down arrow to scroll to "Ramp
Down". Press Select and use the Up or Down
arrow to choose between "Fast", Medium or
"Slow". Press Save.
XF
®
VSF Variable Speed and Flow Pump Installation and User' s Guide
13