8.1.1 Switching off in an emergency

The SE servers SE x86 comply with the relevant safety regulations for IT equipment, including electrical office
equipment.
In an emergency all the hardware components must immediately be disconnected by cutting off the power
distribution units from the power source (e.g. when the housing or power cable is damaged or liquid or foreign
material gets into the equipment).
!
CAUTION!
Operation of the SE server SE x86 is then terminated ungracefully and abruptly.
Notify Customer Support.
If despite the emergency there is still time enough, you can also switch off Server Unit(s), Application Unit(s) and
Management Unit manually via the operating panel at the front of the unit (for the MU see
the SU and AU see the "Server Unit x86" [ ] and "Additive Components" Operating Manuals [ ]). Optional hardware
components have their own On/Off switches or are switched on/off automatically together with the Server Unit (e.g.
ETERNUS JX40, see "Additive Components" [ ]).
!
CAUTION!
These do not disconnect the hardware components completely from the power source. To cut the entire
system off from the power source, you must must disconnect the power distribution units from the power
source.
Notify Customer Support.