8.2.2 Switching the SE server on

The figure below shows the hardware involved in switching the Server Unit /390 on/off.
Figure 44: Hardware involved in switching the Server Unit /390 on/off
Detailed information on switching the hardware on/off using the SE Manager is provided in the "Operation and
Administration" manual [ ].
5
The following hardware components must be switched on in the specified order.
1. Switch on the optional hardware components
> Switch on the ETERNUS LT140 resp. ETERNUS LT40 S2 tape library using the On/Off switch at the front
(see the "Additive Components" Operating Manual [ ]).
> Switch on any other connected hardware components.
2. Switch on the MU
The power-on indicator (item 11 in
> Switch on the rack console by pulling out and folding out the monitor, see
> Press the On/Off switch on the MU (item 12 in
The power-on indicator lights up green. The MU switches itself on, conducts a system test and starts the
M2000 software. This takes a little time. Finally, on the rack console you see the login window for the Linux
desktop of the local console.
4
figure 16
resp. item 8 in
figure 17/18
figure 16
) lights up orange (POWER STAND-BY).
"Rack console"
resp. item 7 in
figure 17/18
.
).
85