6.2
Switching the server node on and off
The multi-node server system consists of up to two server nodes. Each server
node installed in the server enclosure works independently.
V
CAUTION!
It nothing appears on the screen but flickering stripes after switching
●
on the server node, switch the server node off immediately (see
chapter
The On/Off button does not disconnect the server node from the
●
mains voltage. To completely disconnect it from the mains voltage,
remove the power plug(s) from the socket(s).
Do not move, strike, or shake the server node when it is turned on.
●
This can damage the hard disk in the server node and cause data
loss.
Turn the server node on when the temperature is in its operating
●
environment range (+10 °C ... +35 °C). For details on the operating
environment, refer to "Safety Precautions". When operating the
device outside of this operating environment, the server node may
operate improperly, damage data etc. Furthermore, Fujitsu cannot be
held responsible for any related damage, malfunction, or loss of data,
etc.
Be sure to wait for 10 seconds or more after shutdown before turning
●
the server node on.
After connecting the power cable, press the On/Off button after it
●
passes for more than 10 seconds.
Switching the server node on
Ê Connect a USB storage medium (hard disk drive, optical drive or flash
media) containing a bootable image to your server.
Ê Press the On/Off button.
The power-on indicator lights up green when the server node is connected to
the mains.
I
Alternatively, the power can be switched on/off on the chassis front panel
of the PRIMERGY CX400 S1 server enclosure.
CX270 S1
"Troubleshooting and tips" on page
Operating Manual
Starting up and operation
55).
47