Cabinet Row Quantity; Cabinet Column Quantity; Port 1 Cabinet Quantity; Cabinet Quantity Charts - Chauvet DJ Vivid Drive 28N User Manual

Hide thumbs Also See for Vivid Drive 28N:
Table of Contents

Advertisement

Cabinet Row Quantity

This setting defines the number of rows of panels (height) connected to the Vivid Drive 28N.
1. Access the
Screen Settings
2. Turn the <MENU> knob until Cabinet Row Qty is selected.
3. Press the <MENU> knob.
4. Turn the <MENU> knob clockwise or counter-clockwise to increase or decrease the number of
rows, from 1–34. (The highest number that can be selected is determined by the Column Quantity
and the firmware of the connected panels. See the
5. Press the <MENU> knob.

Cabinet Column Quantity

This setting defines the number of columns of panels (width) connected to the Vivid Drive 28N.
1. Access the
Screen Settings
2. Turn the <MENU> knob until Cabinet Column Qty is selected.
3. Press the <MENU> knob.
4. Turn the <MENU> knob clockwise or counter-clockwise to increase or decrease the number of
columns, from 1–36. (The highest number that can be selected is determined by the Row Quantity
and the firmware of the connected panels. See the
5. Press the <MENU> knob.

Port 1 Cabinet Quantity

This setting defines the number of panels connected to output port 1 on the Vivid Drive 28N.
1. Access the
Screen Settings
2. Turn the <MENU> knob until Port1 Cabinet Qty is selected.
3. Press the <MENU> knob.
4. Turn the <MENU> knob clockwise or counter-clockwise to increase or decrease the number of
panels, from 1–115. (The number range that can be selected is determined by the Row and
Column Quantities and the firmware of the connected panels. See the
5. Press the <MENU> knob.
The maximum number of LEDs supported by each Port of the Vivid Drive 28N is 655,360.
This amounts to 30 Vivid 4 panels (which are 104x208 pixels) or 60 panels that are 104x104
pixels per Port.

Cabinet Quantity Charts

Vivid 4 Cabinet Quantity Chart
The following chart shows the ranges usable for Row, Column, and Port 1 Quantity, assuming CHAUVET
Vivid 4 panels are in use. Port 1 values exceeding 30 cannot be used for 104x208 pixel panels such as the
Vivid 4. Available values may exceed the recommended values.
Total
Row
Col.
2
30
3
20
4
15
5
12
60
6
10
15
4
10
6
12
5
58
2
29
57
3
19
2
28
4
14
56
7
8
8
7
14
4
5
11
55
11
5
Page 13 of 37
menu.
menu.
menu.
Port 1
Total
Row
2
3
4
36
6
30
9
12
5
35
7
34
2
29–30
3
33
11
2
28–30
32
4
8
1
30
2
28–30
3
Cabinet Quantity
Charts.)
Cabinet Quantity
Charts.)
Cabinet Quantity
Col.
Port 1
Total
18
12
9
18
18–30
6
4
3
17
7
18–30
5
16
17
17–30
11
17–30
3
16
15
8
16–30
4
30
15
15–30
14
10
Vivid Drive 28N User Manual Rev. 1
Operation
Charts.)
Row
Col.
Port 1
1
18
2
9
3
6
9–18
6
3
9
2
1
17
9–17
1
16
2
8
8–16
4
4
8
2
1
15
3
5
8–15
5
3
15
1
1
14
2
7
7–14
7
2

Advertisement

Table of Contents
loading

Table of Contents