Oracle E5-APP-B Alarms And Maintenance page 28

Eagle lnp application processor
Hide thumbs Also See for E5-APP-B:
Table of Contents

Advertisement

Alarms and Maintenance
sch311x-isa-0a70
voltage: Voltage is OK. Vccp: +1.04 V (min = +0.85 V, max = +1.35 V), CHIP:
sch311x-isa-0a70
voltage: Voltage is OK. V3.3: +3.27 V (min = +3.13 V, max = +3.47 V), CHIP:
sch311x-isa-0a70
voltage: Voltage is OK. V5: +4.97 V (min = +4.74 V, max = +5.26 V), CHIP:
sch311x-isa-0a70
voltage: Voltage is OK. V1.8: +1.81 V (min = +1.69 V, max = +1.88 V), CHIP:
sch311x-isa-0a70
voltage: Voltage is OK. V3.3stby: +3.28 V (min = +3.13 V, max = +3.47 V),
CHIP: sch311x-isa-0a70
voltage: Voltage is OK. V3.3: +3.29 V (min = +3.13 V, max = +3.46 V), CHIP:
cy8c27x43-i2c-0-28
voltage: Voltage is OK. V1.8: +1.81 V (min = +1.71 V, max = +1.89 V), CHIP:
cy8c27x43-i2c-0-28
voltage: Voltage is OK. V1.5: +1.50 V (min = +1.42 V, max = +1.57 V), CHIP:
cy8c27x43-i2c-0-28
voltage: Voltage is OK. V1.2: +1.20 V (min = +1.14 V, max = +1.26 V), CHIP:
cy8c27x43-i2c-0-28
voltage: Voltage is OK. V1.05: +1.04 V (min = +1.00 V, max = +1.10 V),
CHIP: cy8c27x43-i2c-0-28
voltage: Voltage is OK. V1.0: +1.00 V (min = +0.95 V, max = +1.05 V), CHIP:
cy8c27x43-i2c-0-28
voltage: Server Voltages OK.
Running modules in class net...
defaultroute: Checking default route(s)
defaultroute:
192.168.61.250...
ping: Checking ping hosts
ping: prova-ip network connection OK
ping: provb-ip network connection OK
ping: dsmm-a network connection OK
ping: dsmm-b network connection OK
ping: dsmb-a network connection OK
ping: dsmb-b network connection OK
ping: sync-a network connection OK
ping: sync-b network connection OK
Running modules in class proc...
run: Checking RTCtimeStampd...
run: Found 1 instance(s) of the RTCtimeStampd process.
run: Checking ntdMgr...
run: Found 1 instance(s) of the ntdMgr process.
run: Checking smartd...
run: Found 1 instance(s) of the smartd process.
run: Checking switchMon...
run: Found 1 instance(s) of the switchMon process.
run: Checking atd...
run: Found 1 instance(s) of the atd process.
run: Checking crond...
run: Found 1 instance(s) of the crond process.
run: Checking snmpd...
run: Found 1 instance(s) of the snmpd process.
run: Checking sshd...
run: Found 7 instance(s) of the sshd process.
run: Checking syscheck...
run: Found 1 instance(s) of the syscheck process.
run: Checking rsyslogd...
run: Found 1 instance(s) of the rsyslogd process.
run: Checking tklcTpdCardCfgS...
run: Found 1 instance(s) of the tklcTpdCardCfgS process.
run: Checking alarmMgr...
run: Found 1 instance(s) of the alarmMgr process.
run: Checking tpdProvd...
E76220 Revision 1, July 2016
Checking static default route through device eth01 to gateway
OK