Oracle E5-APP-B Alarms And Maintenance page 25

Eagle lnp application processor
Hide thumbs Also See for E5-APP-B:
Table of Contents

Advertisement

Alarms and Maintenance
System Check
Memory
Network
Process
Hardware Configuration
Cooling Fans
Voltages
Temperature
MPS Platform
E76220 Revision 1, July 2016
Function
mounted and perform checks accordingly.
Failures in the file system are reported if certain
thresholds are exceeded, if the file system size is
incorrect, or if the partition could not be found.
Alarm thresholds are reported in a similar
manner.
Verify that 8 GB of RAM is installed.
Verify that all ports are functioning by pinging
each network connection (provisioning, sync, and
DSM networks). Check the configuration of the
default route.
Verify that the following critical processes are
running. If a program is not running the minimum
required number of processes, an alarm is
reported. If more than the recommended
processes are running, an alarm is also reported.
• sshd (Secure Shelldaemon)
• ntpd (NTPdaemon)
• syscheck (System Health Check daemon)
Verify that the processor is running at an
appropriate speed and that the processor matches
what is required on the server. Alarms are
reported when a processor is not available as
expected.
Verifies no fan alarm is present. Fan alarm will
be issued if fans are outside expected RPM.
Measure all monitored voltages on the server main
board. Verify that all monitored voltages are
within the expected operating range.
Measure the following temperatures and verify
that they are within a specified range.
• Inlet and Outlet temperatures
• Processor internal temperature
• MCH internal temperature
Provide alarm if internal diagnostics detect any
other error, such as server syscheck script
failures.
Maintenance
25

Advertisement

Table of Contents
loading

Table of Contents