SECTION 3 - TROUBLESHOOTING AND FAULT CODES
G - Ventilation fans do not work
Check fuse F2 and check the fan timer "T1". If
they are ok, check connection from the 12 Volt
Lead-acid battery to the BMS (Feed connector –
R1 – R4 – T1 5 ways BMS connector – BMS).
H - Battery charger does not work correctly
Connect the power cable and check the battery
charger light after two minutes, if it is red go to
step 6, if it is red/green go to step 7.
26. Light on battery charger is red, two minutes after
connecting the power cable.
If the light on battery charger is red, go to step 6.
27. Light on the battery charger is flashing red/
green two minutes after connecting the power
cable.
If the light on battery charger flashes red/green,
go to step 7.
3-24
I - Plug icon on the display interchanges intermit-
tently with the battery icon while charging
Check the value "battery %" in the INPUT menu,
press button number 6 "service", press 1 "input",
and 1 "previous". Press 9 "Esc" to go back.
MAF12020
If during charge, the battery level is changing
irregularly from 100% to another value, go to
step 21. If during charge, the battery level is not
100%, leave the machine under charge over-
night.
L - Battery package level is "zero" on the remote
control, however the machine works properly
Check all the connections and the feeds on the
"Can Bridge Box".
MAF12120