Battery Pack (Sn C170000330 To Present) - JLG X390AJ-X14J Supplement Manual

Table of Contents

Advertisement

48V Battery Pack (SN C170000330 to Present)
A - Remote control display is OFF
1. With the key switch in ON position, open the
main board electric box, and check the LED on
the main board.
If ON go to step 2
If OFF go to step 3
2. LED on the main board are ON
If the LED are ON then the main board is also ON,
so the remote control failure is not because of
the Lithium system. Refer the wiring diagram to
check the remote control feed.
3. LED on the main board are OFF
Check the 12V Lead-acid battery; it supplies
power to all the boards during the ignition, so if
it is not OK, the machine will remain off.
Check the voltage on the 12V switch under the
key switch. IF red wire to the ground has 12 Volt,
go to step 4, if not go to step 5.
31215460
SECTION 3 - TROUBLESHOOTING AND FAULT CODES
4. Red wire has 12 Volt
5. Red wire does not have 12 Volt
B - Battery package level is "zero" even after the
charge
MAF12060
6. Connect the power cable, the battery charger
7. Connect the power cable, the battery charger
MAF12070
Check the 12 Volt switch under the key switch,
and check the connection of the wire OR0400 (or
1/12), from the key switch to the pin B1 in the
master board.
Check fuse F6, then check the supply from 12V
Lead-acid battery to fuse F6 (= Lead-acid battery
+ feed connector + R1 + 2 ways connector).
Check the value in the INPUT menu, press button
number 6 "service", then press 1 "input", then 1
"previous". Press button number 9 "Esc" to go
back.
If external electrical power is available, connect
the 110-220V power cable, and check the bat-
tery charger light after two minutes;
If the battery charger light flashes red, go to step
6.
If the battery charger light flashes green/red, go
to step 7.
light is red after two minutes.
The system works correctly. Keep the power
cable connected until the light on the battery
charger will flash yellow. Test the machine again,
if the problem remains, go to step 9.
light flashes red/green after two minutes.
This condition indicates the battery charger
does not find the 48 Volt battery package. Check
fuse F1, then check fuse F3, then check the wire
"123" connected from the pin no. 5 of the "6
ways BC connector" to the wire "111" pin no. 2 of
the "5 ways BMS connector" of the BMS. Check
MAF12080
3-15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents