SECTION 3 - TROUBLESHOOTING AND FAULT CODES
Table 3-1. BMS Fault Codes (1st and 2nd Generation Battery Pack)
Below are some examples of BMS error
• 02 - Unexpected Voltage
When one cell reaches 3650 mV, the BMS will dis-
connect the lithium pack and the system will
show the "UNEXPECTED VOLTAGE" error. This
could be caused by BMS failure to not identify
one cell or cannot connect it to the discharging
resistance.
3-2
Error Code
01
System Configuration Error
02
Unexpected Voltage
03
Unexpected Temperature
04
Overcurrent Discharge
05
Overcurrent Charge
06
Pre-charge Error
07
No 12 Volt Supplies
08
No 12 Volt Supplies
09
Battery Over temperature
10
Electronics Over temperature
11
Bad Temp Sensor Auto Shut Off Mode
12
All Temp Sensor Broken
13
Broken Temperature Sensor Detected
14
Grunding Fault Error
15
No Bootloader Error
16
Second Protection
17
Watchdog Error
18
Power Board Alarm
19
I2C Module Not Ready
20
I2C TX Error
21
I2C RX Error
22
I2C RX Error 2
23
AD Error
99
General Error
NOTE: When the display shows a BMS fault code, analyze the system
by connecting RamHino software to the machine.
Error Description
• 05 - Overcurrent Charge
If the lithium pack is warm, and one cell is at the
maximum voltage, and the battery charger is
suddenly connected for a while, one impulse of
current will be supplied to the pack. This could
cause the system to show the "OVERCURRENT
CHARGE" error.