Door Switch - KitchenAid Ensemble KGHS01PMT/WH Technical Education

Front-loading gas and electric dryers
Table of Contents

Advertisement

Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.

DOOR SWITCH

Refer to page 4-6 for the procedure for servic-
ing the door switch.
1. Set the dryer to the "Diagnostic Test Mode"
(refer to the procedure on page 6-2).
2. Open and close the dryer door. You should
hear a "beep" each time the door is closed
and opened, and "OE" should be displayed
in the console window whenever the door
is opened.
If a beep does not sound, or if "OE" is dis-
played with the door closed, check the wir-
ing between the door switch and the elec-
tronic control board for positive connec-
tions or short circuits.
If the wiring is okay, perform the resistance
tests.
Door Switch Connector
Door Switch
WARNING
Electrical Shock Hazard
Resistance Tests
1. Unplug dryer or disconnect power.
2. Turn off gas supply to dryer.
3. Close the dryer door.
4. Disconnect the 3-wire connector from the
door switch to the electronic control board.
5. Set the ohmmeter to the R X 1 scale.
Refer to the illustration below for the following
tests.
6. Touch the black ohmmeter test lead to the
white wire pin in the connector and leave
it there for the remaining tests.
7. Touch the red ohmmeter test lead to the
brown wire pin in the connector. The meter
should indicate an open circuit (infinite).
8. Touch the red ohmmeter test lead to the
blue wire pin in the connector. The meter
should indicate a closed circuit (0 ohms).
9. Open the dryer door.
10. Touch the red ohmmeter test lead to the
blue wire pin in the connector. The meter
should indicate an open circuit (infinite).
11. Touch the red ohmmeter test lead to the
brown wire pin in the connector. The meter
should indicate a closed circuit (0 ohms).
12. If the resistance test is incorrect, replace
the wire and door switch assembly, (see
page 4-6 for the procedure), and retest.
White (COM)
CONNECTOR
Brown (N.C.)
Blue (N.O.)
5-6
DOOR OPEN
N.O.
Blue
COM
N.C.
Brown
DOOR CLOSED
N.O.
Blue
COM
N.C.
Brown
White
White

Advertisement