KitchenAid Ensemble KGHS01PMT/WH Technical Education page 18

Front-loading gas and electric dryers
Table of Contents

Advertisement

Electrical Connection Options
If your home has:
And you will be
connecting to:
4-wire receptacle
A UL listed,
(NEMA Type 14-30R)
120/240 volt
minimum, 30
amp, dryer
power supply
cord*
4-wire direct
A fused
disconnect or
circuit breaker
box*
5"
(12.7 cm)
3-wire receptacle
A UL listed,
(NEMA type 10-30R)
120/240 volt
minimum, 30
amp., dryer
power supply
cord*
3-wire direct
A fused
disconnect or
circuit breaker
box*
1
3 / "
2
(8.9 cm)
* If local codes do not permit the connection of
a frame-grounding conductor to the neutral
wire, go to "Optional 3-Wire Connection"
section.
4-Wire Connection: Power Supply Cord
IMPORTANT: A 4-wire connection is required
for mobile homes and where local codes do not
permit the use of 3-wire connections.
2
1
3
4
1. 4-wire receptacle (NEMA type 14-30R)
2. 4-prong plug
3. Ground prong
4. Neutral prong
5. Spade terminals with upturned ends
6. 3/4" (1.9 cm) UL listed strain relief
7. Ring terminals
Go to Section
4-wire connection:
Power supply cord
4-wire connection:
Direct Wire
3-wire connection:
Power supply cord
3-wire connection:
Direct Wire
6
5
7
2-8
1.
Remove center terminal block screw.
2.
Remove appliance ground wire (green
with yellow stripes) from external ground
conductor screw. Fasten it under center,
silver-colored terminal block screw.
1
1. External ground conductor screw- Dotted line
shows position of NEUTRAL ground wire
before being moved to center terminal block screw
2. Center silver-colored terminal block screw
3. Green/yellow wire of harness
3.
Connect ground wire (green or bare) of
power supply cord to external ground con-
ductor screw. Tighten screw.
4.
Connect neutral wire (white or center wire)
of power supply cord under center screw
of the terminal block.
1
2
3
1. External ground conductor screw
2. Green or bare copper wire of power supply cord
3. 3/4" ( 1.9 cm) UL listed strain relief
4. Center silver-colored terminal block screw
5. Neutral grounding wire (green/yellow)
6. Neutral wire (white or center wire)
5.
Connect the other wires to outer terminal
block screws. Tighten screws.
6.
Tighten strain relief screws.
7.
Insert tab of terminal block cover into slot
of dryer rear panel. Secure cover with
hold-down screw.
2
3
4
5
6

Advertisement