KitchenAid Ensemble KGHS01PMT/WH Technical Education page 21

Front-loading gas and electric dryers
Table of Contents

Advertisement

3.
Place the hooked ends of the other power
supply cable wires under the outer termi-
nal block screws (hook facing right).
Squeeze hooked ends together. Tighten
screws.
4.
Tighten strain relief screws.
5.
Insert tab of terminal block cover into slot
of dryer rear panel. Secure cover with
hold-down screw.
Optional 3-Wire Connection
Use for direct wire or power supply cord
where local codes do not permit connect-
ing cabinet-ground conductor to neutral
wire.
1.
Remove center terminal block screw.
2.
Remove appliance ground wire (green
with yellow stripes) from external ground
conductor screw. Connect appliance
ground wire and the neutral wire (white or
center wire) of power supply cord/cable
under center, silver-colored terminal block
screw. Tighten screw.
3.
Connect the other wires to outer terminal
block screws. Tighten screws.
4.
Tighten strain relief screws.
5.
Insert tab of terminal block cover into slot
of dryer rear panel. Secure cover with
hold-down screw.
6.
Connect a separate copper ground wire
from the external ground conductor screw
to an adequate ground.
1
1. External ground conducto r screw
2. Neutral grounding wire (green/yellow)
3. Neutral wire (white or center wire)
4. Grounding path determined by a qualified electrician
2-11