LOCATION REQUIREMENTS
WARNING
Explosion Hazard
Keep flammable materials and vapors,
such as gasoline, away from dryer.
Place dryer at least 18 inches (46 cm)
above the floor for a garage installation.
Failure to do so can result in death,
explosion, or fire.
You will need
• A location that allows for proper exhaust
installation. A gas dryer must be exhausted
to the outdoors. See "Venting Requirements."
• A separate 30 amp circuit (electric dryers
only).
• A grounded electrical outlet located within
2 ft. (61 cm) of either side of the dryer. See
"Electrical Requirements."
• A sturdy floor to support the total dryer weight
of 200 lbs. (90.7 kg). The combined weight of
a companion appliance should also be con-
sidered.
• A level floor with a maximum slope of 1" (2.5
cm) under entire dryer. If slope is greater
than 1" (2.5 cm), install Extended Dryer Feet
Kit, Part Number 279810. Clothes may not
tumble properly and automatic sensor cycles
may not operate correctly if dryer is not level.
• For a garage installation, you will need to
place the dryer at least 18" (46 cm) above
the floor. If using a pedestal, you will need an
additional 6" (15.24 cm).
Do not operate your dryer at temperatures
below 45°F (7°C). At lower temperatures, the
dryer might not shut off at the end of an auto-
matic cycle. This can result in longer drying
times.
The dryer must not be installed or stored in an
area where it will be exposed to water and/or
weather.
Check code requirements. Some codes limit,
or do not permit, installation of the dryer in
garages, closets, mobile homes, or sleeping
quarters. Contact your local building inspector.
NOTE: No other fuel-burning appliance can be
installed in the same closet as a dryer.
Installation Clearances
• The location must be large enough to fully
open the dryer door.
• Additional spacing should be considered for
ease of installation and servicing.
• Additional clearances might be required for
wall, door and floor moldings.
• Additional spacing of 1" (2.5 cm) on all sides
of the dryer is recommended to reduce noise
transfer.
• Companion appliance spacing should also
be considered.
Dryer Dimensions
*
-1/2"
* Most installations require a minimum 5-1/2"
(14 cm) clearance behind the dryer for the
exhaust vent with elbow. See "Venting Re-
quirements."
2-2