Download Print this page

Lindy 38350 User Manual page 5

12 slot seamless modular matrix & modular boards

Advertisement

User Manual
Installation
The Lindy 12 slot modular matrix may require significant assembly depending on your chosen
installation. Please ensure this is undertaken by qualified personnel, while also ensuring the appropriate
safety steps are taken to avoid any static discharge. Please install all required boards prior to connection
of power. If adding or removing any boards, please power the unit down and unplug as this chassis is
not hot pluggable. We also advise that any terminal connections are ran and terminated in advance of
connecting power.
Please ensure all connected source devices, display and other equipment are powered down before
making any connections.
Once the desired layout of boards is fitted please follow the guide below for installation:
1. Connect an HDMI source device or HDMI equipment to the HDMI Input port of the Input board
using HDMI cable.
2. Connect HDBaseT transmitters to the HDBaseT input ports of the HDBaseT input boards using
Cat.X cable.
3. Connect an audio device to the analogue audio input ports on the input boards for audio
embedding.
4. Connect an HDMI display, projector or devices to the HDMI output port of the out board using
HDMI cable.
5. Connect HDBaseT receivers to the HDBaseT output ports of the output boards using Cat.X
cable.
6. Connect digital and/or analogue audio devices to the audio output ports on the output boards for
audio de-embedding.
7. Connect the country specific AC power cord and power on the matrix by pushing the Power
button on the front chassis panel. The front panel LED will show Lindy 38350 for around 5
seconds, then show IIIIIIII0000 and 1~12 in alternate patterns in intervals of 2 seconds. The
LEDs will then show the configuration of the input & output boards. The matrix is now ready for
operation.
8. Switch between sources and displays using the various methods of switching. For a detailed
manual on these methods please see the manual on your local Lindy website.
9. If using the IR extension, please connect IR receiver cable to the IR Extension port of the chassis
and ensure the eye is in clear line of sight.
Please note: 1-12 is red from left to right on both the front and rear of the chassis. 1 on the front panel
label will correspond with the 1st empty slot on the rear of the unit. On the LED panel, No.1 will always
represent the first connected board when viewing from the left of the rear of the unit. If this board is
removed, NO.1 will become the next connected board.