User Manual
RS-232/API Control
Please follow the general setup rules for RS-232 control
▪
Command strings typically are not case-sensitive
▪
All command strings must end with the Take command "T" which will tell the system to execute the
command.
▪
"O" is the letter O, not the number zero (0)
▪
Entering "X" at any point in a command string cancels the command.
▪
A command cannot be cancelled after the "T" has been entered.
▪
Command strings cannot be edited. If a mistake has been made, enter an "X" and then re-enter the
command.
▪
To specify multiple outputs, inputs, levels, or local pre-sets, enter a space "" between each number.
Multiple inputs are only valid in Disconnect commands.
▪
To specify a range of outputs, inputs, or local pre-sets, insert a colon ":" between the lowest and
highest numbers of the range (not supported if the command is otherwise invalid, e.g., cannot specify
a range of inputs in a Change command; the first input only would be routed.).
▪
Colons ":" and spaces "" can be used in the same command string.
▪
If the level designation "L" is omitted, the command is executed on the default level, which is
normally Level 0."
Default RS-232 Settings
The default setting for RS232 port are:
Parameters
Baud Rate
Data bits
Parity
Stop bits
Flow control
Command Instructions
SET SW In Out (CR/LF):
1: [SET SW] are command key words where Lindy recommend using capital letters.
2: [in out] is the parameter. We would recommend using lower case letters.
3:'\r\n' or '\r' or '\n' to finish the command is acceptable.
4: Use spaces where needed. ※ is a space.
5: Fixed parameter. SET SW in out[CR/LF]. Only 2 parameters can be accepted.
Value
9600 bps
8 bits
None
1 bit
None
English