Download Print this page

Lindy 38350 User Manual page 21

12 slot seamless modular matrix & modular boards

Advertisement

User Manual
Set CEC
auto power
Command:
on / off
SET AUTOCEC_FN out prm[CR/LF]
Return:
AUTOCEC_FN out prm[CR/LF]
Parameter:
※ out = {out1~out11,all};
※ prm = {on,off}
Description:
Set sink auto power Function ON or OFF
Get CEC
Auto Power
Command:
On/Off
GET AUTOCEC_FN out[CR/LF]
Status
Return:
AUTOCEC_FN out prm[CR/LF]
Parameter:
※ out = {out1~out11,all};
※ prm = {on,off}
Description:
Get Sink auto power Function ON or OFF Status.
Set CEC
Power
Command:
Delay Time
SET AUTOCEC_D out prm[CR/LF]
Return:
AUTOCEC_D out prm[CR/LF]
Parameter:
※ out = {out1~out11,all};
※ prm = {1,2,3...,}// according to the actual time
counter,1 means 1 minute ,2 means 2 minutes,
Default wait time is 2 minutes, Max wait time is 30
minutes.
Description:
AUTOCEC_D is short for CEC auto Power Delay
Timing
Syntax
Syntax
Syntax
Example
Command:
SET AUTOCEC_FN out1 on[CR/LF]
Return:
AUTOCEC_FN out1 on[CR/LF]
Description:
Set sink auto power ON
Example
Command:
GET AUTOCEC_FN out1[CR/LF]
Return:
AUTOCEC_FN out1 on[CR/LF]
Description:
Get Sink auto power status,and the
status is ON.
Example
Command:
SET AUTOCEC_D out1 2[CR/LF]
Return:
AUTOCEC_D iout1 2[CR/LF]
Description:
when no active signal to out1, 2
minutes later, the unit will auto
power off.