USER MANUAL
OAKWORKS
®
DTPM 300 Imaging Table
made in the USA
with US & imported parts
www.oakworksmed.com · 717.235.6807

Advertisement

Table of Contents
loading

Summary of Contents for OAKWORKS DTPM 300

  • Page 1 USER MANUAL OAKWORKS ® DTPM 300 Imaging Table made in the USA with US & imported parts www.oakworksmed.com · 717.235.6807...
  • Page 2 ® damages in connection with or arising out of the furnishing, performance, or OAKWORKS is a registered use of this document and the program ® trademark of OAKWORKS , Inc. material which it describes. ®...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Product Use Description ....................Contraindications ......................Important Safety Instructions Symbol Identification ....................Safety Instructions ....................Product Description & Photo DTPM300 - Polycarbonate Top ..................Installation Grounding ........................Directions for Use Foot Control Operations ..................6 Hand Control Operations ..................7 Manual Longitudinal Travel Operation ..............
  • Page 4: Product Use Description

    P R O D U C T U S E D E S C R I P T I O N The Oakworks® Fluoroscopy table with Trendelenburg feature is a radiographic table intended for use with mobile or compact stationary C-arm Fluoroscopy Systems where the x-ray generator is located below the table top.
  • Page 5 IMPORTANT SAFETY INSTRUCTIONS I M P O R T A N T S A F E T Y I N S T R U C T I O N S CAUTION READ AND SAVE THESE INSTRUCTIONS Improper use of this device can cause injury. Be sure to read all operating instructions prior to use. Duty Cycle: Max.
  • Page 6 3. Never operate this furnishing if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water. Contact Oakworks Customer Service before use. 4. Keep the cord away from heated surfaces.
  • Page 7: Product Description & Photo

    PRODUCT DESCRIPTION DTPM300 Polycarbonate Top Polycarbonate Top Electronic Lift Towers Locking Casters Optional T-Rails OPTIONS STANDARD SPECIFICATIONS 5” (12.5 cm.) Locking Casters Motion 1 Powered 24”-40” (61-101 cm.) Height Range 6”, 20”, 78” (15.3 cm, 50.8 cm, 198.1 cm) or custom T-Rails Lengths Motion 2 Powered ±14°...
  • Page 8: Installation

    INSTALLATION The Imaging tables come completely assembled and ready to use. Plug the cord into a functioning outlet that is rated for the table. (see Grounding below) Arrange the power cord and control cords so that they will not create a tripping hazard and where the controls are located to your liking and are conveniently accessible.
  • Page 9: Directions For Use

    DIRECTIONS FOR USE The Oakworks Fluoroscopy Table with Trendelenburg positioning offers a variety of positioning ® capabilities for diagnostic x-ray imaging and imaging during therapeutic procedures. DANGER Should the use of this device create a circumstance under which the patient could be overexposed to ionizing radiation, discontinue use immediately and determine an alternative radiology table or alter- native x-ray generating source to use.
  • Page 10: Hand Control Operations

    DIRECTIONS FOR USE H A N D C O N T R O L O P E R A T I O N S CAUTION When lowering the chair or using the Trendelenburg functions, make sure there is nothing that can impede motion (like stools, cabinets, accessory parts, cleaners, etc.) When operating the table’s controls, be sure to observe all cautions and warnings.
  • Page 11: Manual Longitudinal Travel Operation

    DIRECTIONS FOR USE M A N U A L L O N G I T U D I N A L T R A V E L O P E R A T I O N CAUTION When operating the table’s locking knob be sure to avoid pinching. Keep your fingers and other materials clear from the pinch point.
  • Page 12: Top Pad Removal

    DIRECTIONS FOR USE T O P P A D R E M O V A L Remove the Top Pad by pulling the flaps at the underside of the table on either end until the Hook and Loop Faster detaches. Replace the pad by first centering on the table and then pressing the flaps in place, anchoring the flaps to the Fastener Hook and Loop Faster as shown.
  • Page 13: Carbon Fiber Arm Board

    Do not place undue weight or downward pressure on the Fluoro Extender. It is a positioning device for the arms and should not be used as leverage to get on or off the table. Injury can occur. The Oakworks Fluoro Extender is radiolucent and offers extra width only where you need it for great- ®...
  • Page 14: Spine Positioning System Ii

    DIRECTIONS FOR USE S P I N E P O S I T I O N I N G S Y S T E M I I (A C C E S S O R Y) For directions on the use of the Spine Positioning System, see publication “Spine Positioning System” Part number MMMMNUP0003 CONTOURED TORSO SUPPORT PAD...
  • Page 15: Reference

    REFERENCE U S A B L E I M A G I N G A R E A CENTERED FOR A-P VIEW: [16.57 CM] [16.57 CM] 12.01" 37.93" 12.01" [30.52 CM] [96.33 CM] [30.51 CM] 19.88" [50.48 CM] CENTERED OBLIQUE 30º VIEW FROM VERTICAL 6.52"...
  • Page 16 REFERENCE OFFSET FOR A-P VIEW: OFFSET CAUDAL 30º VIEW FROM VERTICAL...
  • Page 17: Cleaning & Disinfection

    To reduce the risk of electric shock: DANGER - Always unplug this furnishing from the electrical outlet before cleaning. The following cleaners were tested by OAKWORKS ® and found to be acceptably compatible with all materials used in construction of our tables: Formula 409 ®...
  • Page 18: Cleaning Process

    - Always unplug this furnishing form the electrical outlet before cleaning. ® Follow the cleaners/disinfectant manufacturers’ directions for use. Please note that cleaning and disinfecting an OAKWORKS table is a two part process. First it must be cleaned of any visible soil, then it can be disinfected. The table should be cleaned as soon as possible after use.
  • Page 19: Model Number & Serial Number

    MODEL NUMBER & SERIAL NUMBER M O D E L & S E R I A L N U M B E R S Serial Number Model Number 16796025 FLDTRT242478MGTTZZ Ser#: FLR561910 DTPM RT 24 x 24-40 x 78 MG/TT TTCoal 01/04/2013 Order#:654321 Notes: Sample Product Label Model Numbers and Serial Numbers always start with a letter.
  • Page 20: Specifications

    SPECIFICATIONS PRODUCT SPECIFICATIONS Materials of Construction This product contains no latex. Top Frame Extruded aluminum with powdercoated or anodized surfaces. Table Top .5” (1.3 cm.) Polycarbonate Patient Comfort 1” (2.5 cm.) upholstered foam pad Table Length 78” (198 cm.) Table Width 24”...
  • Page 21: Guidance And Manufacturer's Declaration - Electromagnetic Emissions

    SPECIFICATIONS Guidance and Manufacturer’s Declaration - Electromagnetic Emissions The table is intended for use in the electromagnetic environment specified below. The customer or the user of the table should assure that it is used in such an environment. Emissions Test Compliance Electromagnetic environment - guidance The table uses RF energy only for its internal...
  • Page 22: Guidance And Manufacturer's Declaration - Electromagnetic Immunity

    SPECIFICATIONS Guidance and manufacturer’s declaration - electromagnetic immunity The table is intended for use in the electromagnetic environment specified below. The customer or the user of the table should assure that it is used in such an environment. Electromagnetic Immunity Test IEC 60601 test level Compliance level environment - guidance...
  • Page 23 SPECIFICATIONS Guidance and manufacturer’s declaration - electromagnetic immunity The table is intended for use in the electromagnetic environment specified below. The customer or the user of the table should assure that it is used in such an environment. Electromagnetic Immunity Test IEC 60601 test level Compliance level environment - guidance...
  • Page 24: Contact Information

    USER MANUAL OAKWORKS ® DTPM300 Imaging Table C O N T A C T I N F O R M A T I O N: Oakworks Inc. ® 923 East Wellspring Road New Freedom, PA 17349 Phone: 717-235-6807 FAX: 717-235-6798 www.oakworksmed.com...