Available languages

Available languages

on a 230 V/50 Hz AC supply. Only qualified
electricians (to VDE 0100) are permitted to carry
out work on the 230 V mains. Applicable accident
prevention regulations must be complied with whilst
such work is being carried out.
To avoid electric shock, disconnect the mains
voltage prior to starting work on the device (trip the
miniature circuit-breaker).
Noncompliance with the installation instructions
can cause fire or introduce other hazards. The
device may only be operated indoors and must be
protected from the effects of damp and dust, as
well as solar or other methods of heat radiation.
It is vital to bear the connected load in mind! The
dimmer is only suitable for incandescent lamps, HV
halogen lamps, LV halogen lamps with electronic
transformers and dimmable energy-saving lamps.
The device has not been designed to support
safety disconnection. The load is not isolated from
the mains. If the dimmer is to be operated with
electronic transformers, only those which meet the
requirements of DIN EN 61347-1 (VDE 0712-30,
Part 1) along with DIN EN 61047 /VDE 0712-25,
Part 2) may be used.
Do not exceed the capacity specified for the
23