C. Control Display Mode ('1')
• To select an item, press the appropriate number on the numeric keypad and then the Start key.
• To deselect an item, press the Clear key.
• A press on the Start key while a description of the selected service mode is indicated will execute
appropriate copying operations.
No.
Service mode
101
Jam location
103
Primary current buffer display
104
Primary charging voltage display
105
Primary current display
106
Intensity display
107
Jam history
108
Error history (E indications)
109
Fixing main thermistor (TH1) detection
temperature
110
Fixing target temperature
112
AE sensor output
113
ROM version No.
114
ROM release No.
116
AE scan intensity display
120
Jam interval
121
Jam paper size data
123
Jam document handler copying data
Indicates the jam location on the copy counter
indicator. (See the next page.)
unit: µA

unit: V

To obtain the actual primary charging voltage, put the
indicated value into negative and subtract 1000.
unit: µA
unit: lux
To obtain the actual intensity (lux), divide the indi-
cated value by 100.
See the next page.
Indicates a history of the most recent ten errors. A
press on the '1', '2', or '3', '4', '5', '6', '7', '8', '9' or '0'
key on the numeric keypad will indicate either of the
most recent, second most recent, or through tenth
most recent error.
unit: °C
unit: °C
Normal if the value changes for each original when
making copies in AE.
Indicates the parts revision number of the ROM.
Indicates the version of the program.
Normal if between '68' and '72'.
Table 7-702
SERVICE MODE
Description
7–3