No.
312
Left/right margin adjustment
(reduction; the movement of the
blanking slide shutter)
313
Primary output voltage correction
(correction against the output
voltage determined on APVC)
314
APVC measurement current shift
(correction against APVC results)
315
APVC measurement voltage
correction (correction against
measurement voltage added for
APVC)
316
APVC measurement current
correction (correction against the
current value measured during
APVC)
318
Transfer output voltage adjustment
(correction against the transfer
voltage determined by ATVC)
319
Multifeeder arch adjustment (timing
at which the pick-up roller is turned
OFF)
320
Cassette 1/2 pick-up arch adjust-
ment (timing at which the pick-up
roller turns OFF)
321
Cassette 3 pick-up arch adjustment
(timing at which the pick-up roller
turns OFF)
322
Cassette 4 pick-up arch adjustment
(timing at which the pick-up roller
turns OFF)
323
Cassette 5 pick-up arch adjustment
(timing at which the pick-up roller
turns OFF)
Item
–10 ~ +10
–16 ~ +16
–40 ~ +40
–16 ~ +16
–10 ~ +10
Table 7-712-2
Settings
A higher setting increases both left and
right margins.
default:
unit: 0.27 mm
Enter the value recorded on the label
attached to the drum cartridge whenever
you have replaced the drum cartridge.
default:
Enter the value recorded on the label
attached to the drum cartridge whenever
you have replaced the drum cartridge.
default:
default:
unit: 16 V
Execute it when replacing the composite
power supply, and enter the value indicated
on the label attached to the composite
power supply.
default:
Execute it when replacing the composite
power supply, and enter the value indicated
on the label attached to the composite
power supply.
Execute when replacing the composite
–4 ~ +4
power supply by converting the value
indicated on the label attached to the
composite power supply as follows:
default:
Value on label Input value
1
2
3
4
5
A higher setting increases arching.
0 ~ 63
default:
unit: 0.27 mm
A higher setting increases arching.
0 ~ 63
default:
unit: 0.27 mm
A higher setting increases arching.
0 ~ 63
default:
unit: 0.27 mm
0 ~ 63
A higher setting increases arching.
default:
unit: 0.27 mm
A higher setting increases arching.
0 ~ 63
default:
unit: 0.27 mm
SERVICE MODE
Description
–2
–4
–10
5
0
0
Value on label Input value
0
6
–1
7
–2
8
–3
9
–4
36
32
10
10
10
7–11
+1
+2
+3
+4